Harmonic source location and meter placement optimization by impedance network approach

被引:8
作者
Dag, O. [1 ]
Ucak, C. [1 ]
Usta, O. [2 ]
机构
[1] Yeditepe Univ, Dept Elect & Elect Engn, TR-34755 Istanbul, Turkey
[2] Istanbul Tech Univ, Dept Elect Engn, TR-34469 Istanbul, Turkey
关键词
Power systems; Harmonics; Source location; Optimal meter placement; TIME-VARYING HARMONICS; POWER-SYSTEMS; STATE ESTIMATION; IDENTIFICATION; CUSTOMER; QUALITY;
D O I
10.1007/s00202-011-0213-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The level of harmonic distortion on modern power systems is a concern as more non-linear devices are used in energy conversion. Therefore, locating the harmonic source is important to identify and to take appropriate actions for eliminating the distortion. Also meter placement is a crucial part of harmonic location problem. The placement approach should both provide limited number of meter locations and overcome misallocation of the source because of the difficulty in obtaining correct network impedances. Consequently, a harmonic source location method by using impedance network approach with a new optimal meter placement algorithm (OMPA) is proposed in this paper. The validation of OMPA for different levels of harmonic impedance errors is performed using Monte Carlo technique and the effectiveness of the algorithm is shown by using IEEE 30-bus test system.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 28 条
[1]   A self-synchronizing instrument for harmonic source detection in power systems [J].
Aiello, M ;
Cataliotti, A ;
Cosentino, V ;
Nuccio, S .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) :15-23
[2]  
[Anonymous], 2002, ELECTR POW SYST RES, DOI DOI 10.1036/007138622X
[3]  
[Anonymous], 1999, 3605 CIGRE, P791
[4]  
[Anonymous], 1993, IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems
[5]   Time-varying harmonics: Part II - Harmonic summation and propagation [J].
Baghzouz, Y ;
Burch, RF ;
Capasso, A ;
Cavallini, A ;
Emanuel, AE ;
Halpin, M ;
Langella, R ;
Montanari, G ;
Olejniczak, KJ ;
Ribeiro, P ;
Rios-Marcuello, S ;
Ruggiero, F ;
Thallam, R ;
Testa, A ;
Verde, R .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (01) :279-285
[6]   Time-varying harmonics: Part I - Characterizing measured data [J].
Baghzouz, Y ;
Burch, RF ;
Capasso, A ;
Cavallini, A ;
Emanuel, AE ;
Halpin, M ;
Imece, A ;
Ludbrook, A ;
Montanari, G ;
Olejniczak, KJ ;
Ribeiro, P ;
Rios-Marcuello, S ;
Tang, L ;
Thallam, R ;
Verde, P .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) :938-944
[7]   DYNAMIC STATE ESTIMATION OF POWER-SYSTEM HARMONICS USING KALMAN FILTER METHODOLOGY [J].
BEIDES, HM ;
HEYDT, GT .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (04) :1663-1670
[8]   Comparison of nonactive powers for the detection of dominant harmonic sources in power systems [J].
Cataliotti, Antonio ;
Cosentino, Valentina ;
Nuccio, Salvatore .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (08) :1554-1561
[9]   A distributed system for electric power quality measurement [J].
Cristaldi, L ;
Ferrero, A ;
Salicone, S .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (04) :776-781
[10]  
Cristaldi L, 1995, IEEE T INSTRUM MEAS, V47, P1335