Bioclimatic design of buildings considering heating requirements in Italian climatic conditions. A simplified approach

被引:38
作者
Albatici, Rossano [1 ]
Passerini, Francesco [1 ]
机构
[1] Univ Trent, Dept Civil & Environm Engn, I-38123 Trento, Italy
关键词
Building shape; Solar exposure; Energy efficiency; Bioclimatic architecture; Parametric approach; FUNCTIONAL STRUCTURE; OFFICE BUILDINGS; SHAPE; OPTIMIZATION; WELL; IMPACT;
D O I
10.1016/j.buildenv.2011.01.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a parametric approach to the definition of a proper building shape compared to the building heating requirement in the very first stage of the design process. A new simplified index is introduced, namely the south exposure coefficient C(fs). In fact, as far as bioclimatic architecture is concerned, the relationship between buildings and natural environment is very important both for the control of indoor comfort conditions and energy requirements. The building shape is a fundamental aspect of this relationship. Usually, in thermal behavior analysis this parameter is considered only from the point of view of compactness. This is a reductive approach, because two buildings with the same coefficient could have different shapes and so a different thermal behavior. Some aspects such as orientation, openings, exposure to atmospheric agents and natural elements must also be strictly considered. Moreover, in scientific literature no indications are given to designers who operate in mild and warm climate conditions. This is why the results of a research activity focused on heating requirements of buildings with different shapes and laid in the Italian territory are presented. Monthly calculations have been performed following the quasi-steady-state method suggested in the European standard. Outputs show that better results in the building energy performance can be achieved considering a bioclimatic (though simplified) approach since the very beginning. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1624 / 1631
页数:8
相关论文
共 14 条
[1]   Impacts of some building passive design parameters on heating demand for a cold region [J].
Aksoy, U. Teoman ;
Inalli, Mustafa .
BUILDING AND ENVIRONMENT, 2006, 41 (12) :1742-1754
[2]   Impact of building shape on thermal performance of office buildings in Kuwait [J].
AlAnzi, Adnan ;
Seo, Donghyun ;
Krarti, Moncef .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :822-828
[3]  
[Anonymous], 2007, 14683 EN ISO
[4]   Design of buildings shape and energetic consumption [J].
Depecker, P ;
Menezo, C ;
Virgone, J ;
Lepers, S .
BUILDING AND ENVIRONMENT, 2001, 36 (05) :627-635
[5]  
EN ISO, 2008, EN ISO 13790
[6]  
ENGSTROM L, 1988, ENERGY BUILT ENV
[7]   Optimization of shape and functional structure of buildings as well as heat source utilisation. Partial problems solution [J].
Jedrzejuk, H ;
Marks, W .
BUILDING AND ENVIRONMENT, 2002, 37 (11) :1037-1043
[8]   Optimization of shape and functional structure of buildings as well as heat source utilization. Basic theory [J].
Jedrzejuk, H ;
Marks, W .
BUILDING AND ENVIRONMENT, 2002, 37 (12) :1379-1383
[9]   Optimization of shape and functional structure of buildings as well as heat source utilisation example [J].
Jedrzejuk, H ;
Marks, W .
BUILDING AND ENVIRONMENT, 2002, 37 (12) :1249-1253
[10]   Multicriteria optimisation of shape of energy-saving buildings [J].
Marks, W .
BUILDING AND ENVIRONMENT, 1997, 32 (04) :331-339