NONINVASIVE IN VIVO LIVER FIBROSIS EVALUATION USING SUPERSONIC SHEAR IMAGING: A CLINICAL STUDY ON 113 HEPATITIS C VIRUS PATIENTS

被引:356
作者
Bavu, Eric [1 ,5 ]
Gennisson, Jean-Luc [1 ]
Couade, Mathieu [2 ]
Bercoff, Jeremy [2 ]
Mallet, Vincent [3 ]
Fink, Mathias [1 ]
Badel, Anne [4 ]
Vallet-Pichard, Anais [3 ]
Nalpas, Bertrand [3 ]
Tanter, Mickael [1 ]
Pol, Stanislas [3 ]
机构
[1] ESPCI ParisTech, Inst Langevin Ondes & Images, CNRS,UMR 7587, INSERM,U979, F-75005 Paris, France
[2] Superson Imagine, Aix En Provence, France
[3] Univ Paris 05, Hop Cochin, Unite Hepatol, INSERM,U567, Paris, France
[4] INSERM UMRS 726 Paris, Equipe Bioinformat Genom & Mol, Paris, France
[5] Conservatoire Natl Arts & Metiers EA 3196, Lab Mecan Struct & Syst Couples, Paris, France
关键词
2-D transient elastography; Shear wave imaging; Shear wave spectroscopy; Ultrasound; Liver fibrosis staging; MAGNETIC-RESONANCE ELASTOGRAPHY; CHRONIC VIRAL-HEPATITIS; TRANSIENT ELASTOGRAPHY; SERUM MARKERS; BIOPSY; ELASTICITY; DIAGNOSIS; MODULUS; FIB-4; VISUALIZATION;
D O I
10.1016/j.ultrasmedbio.2011.05.016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Supersonic shear imaging (SSI) has recently been demonstrated to be a repeatable and reproducible transient bidimensional elastography technique. We report a prospective clinical evaluation of the performances of SSI for liver fibrosis evaluation in 113 patients with hepatitis C virus (HCV) and a comparison with FibroScan (FS). Liver elasticity values using SSI and FS ranged from 4.50 kPa to 33.96 kPa and from 2.60 kPa to 46.50 kPa, respectively. Analysis of variance (ANOVA) shows a good agreement between fibrosis staging and elasticity assessment using SSI and FS (p < 10(-5)). The areas under receiver operating characteristic (ROC) curves for elasticity values assessed from SSI were 0.948, 0.962 and 0.968 for patients with predicted fibrosis levels F >= 2, F >= 3 and F 5 4, respectively. These values are compared with FS area under the receiver operating characteristic curve (AUROC) of 0.846, 0.857 and 0.940, respectively. This comparison between ROC curves is particularly significant for mild and intermediate fibrosis levels. SSI appears to be a fast, simple and reliable method for noninvasive liver fibrosis evaluation. (E-mail: eric.bavu@espci.fr) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1361 / 1373
页数:13
相关论文
共 61 条
[1]   Diagnosing fibrosis in hepatitis C: Is the pendulum swinging from biopsy to blood tests? [J].
Afdhal, NH .
HEPATOLOGY, 2003, 37 (05) :972-974
[2]  
[Anonymous], 2004, WORLD HLTH REPORT 20
[3]   Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging-Preliminary Results [J].
Athanasiou, Alexandra ;
Tardivon, Anne ;
Tanter, Mickael ;
Sigal-Zafrani, Brigitte ;
Bercoff, Jeremy ;
Eux, Thomas Deffi ;
Gennisson, Jean-Luc ;
Fink, Mathias ;
Neuenschwander, Sylvia .
RADIOLOGY, 2010, 256 (01) :297-303
[4]   Liver fibrosis [J].
Bataller, R ;
Brenner, DA .
JOURNAL OF CLINICAL INVESTIGATION, 2005, 115 (02) :209-218
[5]   How to assess liver fibrosis and for what purpose? [J].
Beaugrand, M .
JOURNAL OF HEPATOLOGY, 2006, 44 (03) :444-445
[6]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[7]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[8]  
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[9]   The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force [J].
Bercoff, J ;
Tanter, M ;
Muller, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (11) :1523-1536
[10]   Sonic boom in soft materials: The elastic Cerenkov effect [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
APPLIED PHYSICS LETTERS, 2004, 84 (12) :2202-2204