Analytical aspects of the CEEM soil project

被引:15
作者
Muntau, H [1 ]
Rehnert, A
Desaules, A
Wagner, G
Theocharopoulos, S
Quevauviller, P
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Environm, I-21020 Ispra, Italy
[2] Inst Environm Protect & Agr, Swiss Fed Res Stn Agroecol & Agr, CH-3003 Bern, Switzerland
[3] Univ Saarland, Inst Biogeog, D-66041 Saarbrucken, Germany
[4] Natl Agr Res Fdn, Soil Sci Inst Athens, Athens 14123, Greece
[5] Commiss European Communities, DG 12, SM&T, B-1049 Brussels, Belgium
关键词
D O I
10.1016/S0048-9697(00)00610-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the past, exercises aiming at an assessment of data uncertainty in environmental analysis were usually restricted to the analysis step, while sampling and pre-analytical sample treatment was largely ignored. Collaborative studies on the quantification of sampling errors require, besides a suitable and well characterized test site, the availability of a reference laboratory for the analysis of all of the samples taken in the context of the study by all participants and also test methods which do not contribute large and variable uncertainties due to long and complex analytical methodologies. Here we summarize the major analytical aspects of a European project on the identification and quantification of sampling influences on the determination of lead, cadmium, copper and zinc in soil. The participant group included the leading soil analysis laboratories in Europe; the test site at Dornach (CH) was well suited for the purpose and showed high metal gradients and differentiated land use. The analytical methods (wavelength-dispersive X-ray fluorescence spectrometry and solid-state Zeeman AAS) used in the study showed stable performance characteristics within the confidence interval of the certified reference materials used for the measurement quality control over the entire project period. Additionally, double-blind tests on split samples showed agreement of data in very narrow limits thus demonstrating the reliability of the reference database. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 49
页数:23
相关论文
共 15 条
[1]  
CAPODAGLIO G, 1994, ANN CHIM-ROME, V84, P329
[2]  
Griepink B., 1984, Zeitschrift fur Analytische Chemie, V318, P588
[3]   TRACE-ELEMENT ANALYSIS OF SUSPENDED MATTER COLLECTED ON ORGANIC FILTER MATERIAL BY DIRECT ZEEMAN ATOMIC-ABSORPTION SPECTROSCOPY [J].
GROBECKER, KH ;
MUNTAU, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (07) :728-730
[4]  
JANSSEN A, 1985, FRESEN Z ANAL CHEM, V322, P713
[5]  
KUHNT G, 1994, EUROPEAN COMMISSION
[6]   Uncertainty in analytical results from solid materials with electrothermal atomic absorption spectrometry: A comparison methods [J].
Kurfurst, U ;
Rehnert, A ;
Muntau, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (02) :229-244
[7]   THEORY AND INSTRUMENTATION - AN AUTOMATED SOLID SAMPLE ANALYSIS SYSTEM [J].
KURFURST, U ;
KEMPENEER, M ;
STOEPPLER, M ;
SCHUIERER, O .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :248-252
[8]   INVESTIGATIONS ON THE ANALYSIS OF HEAVY-METALS IN SOLIDS BY DIRECT ZEEMAN ATOMIC-ABSORPTION SPECTROSCOPY .1. AUTOMATIC SAMPLER FOR SOLIDS [J].
KURFURST, U ;
RUES, B ;
WACHTER, KH .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (01) :1-5
[9]  
KURFURST U, 1982, GIT FACHZ LAB, V26, P825
[10]  
KURFURST U, 1980, LABORPRAXIS, V5, P1