Size optimization of a PV/wind hybrid energy conversion system with battery storage using response surface methodology

被引:132
作者
Ekren, Orhan [2 ]
Ekren, Banu Yetkin [1 ]
机构
[1] Pamukkale Univ, Dept Ind Engn, TR-20070 Denizli, Turkey
[2] Ege Univ, Dept HVAC, Ege Vocat Training Sch, TR-35100 Izmir, Turkey
关键词
hybrid energy; optimization; simulation; response surface methodology;
D O I
10.1016/j.apenergy.2008.02.016
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper aims to show the use of the response surface methodology (RSM) in size optimization of an autonomous PV/wind integrated hybrid energy system with battery storage. RSM is a collection of statistical and mathematical methods which relies on optimization of response surface with design parameters. In this study, the response surface, output performance measure, is the hybrid system cost, and the design parameters are the PV size, wind turbine rotor swept area and the battery capacity. The case study is realized in ARENA 10.0, a commercial simulation software, for satisfaction of electricity consumption of the global system for mobile communications (GSM) base station at Izmir Institute of Technology Campus Area, Urla, Turkey. As a result, the optimum PV area, wind turbine rotor swept area, and battery capacity are obtained to be 3.95 m(2), 29.4 m(2), 31.92 kWh, respectively. These results led to $37,033.9 hybrid energy system cost, including auxiliary energy cost. The optimum result obtained by RSM is confirmed using loss of load probability (LLP) and autonomy analysis. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1086 / 1101
页数:16
相关论文
共 31 条
[1]   Optimised model for community-based hybrid energy system [J].
Ashok, S. .
RENEWABLE ENERGY, 2007, 32 (07) :1155-1164
[2]   Sizing of a stand-alone hybrid wind-photovoltaic system using a three-event probability density approximation [J].
Bagul, AD ;
Salameh, ZM ;
Borowy, B .
SOLAR ENERGY, 1996, 56 (04) :323-335
[3]   Technoeconomic assessment of a hybrid solar/wind installation for electrical energy saving [J].
Bakos, GC ;
Tsagas, NF .
ENERGY AND BUILDINGS, 2003, 35 (02) :139-145
[4]   OPTIMUM PHOTOVOLTAIC ARRAY SIZE FOR A HYBRID WIND PV SYSTEM [J].
BOROWY, BS ;
SALAMEH, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (03) :482-488
[5]   Methodology for optimally sizing the combination of a battery bank and PV array in a Wind/PV hybrid system [J].
Borowy, BS ;
Salameh, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (02) :367-373
[6]  
Box GEP., 1987, EMPIRICAL MODEL BUIL
[7]  
Box GEP, 1978, STAT EXPT
[8]   Techno-economic analysis of autonomous PV-wind hybrid energy systems using different sizing methods [J].
Celik, AN .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (12) :1951-1968
[9]   Optimisation and techno-economic analysis of autonomous photovoltaic-wind hybrid energy systems in comparison to single photovoltaic and wind systems [J].
Celik, AN .
ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (18) :2453-2468
[10]   Optimization of a wind/PV hybrid power generation system [J].
Eke, R ;
Kara, O ;
Ulgen, K .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2005, 2 (01) :57-63