Calibration of solid-phase microextraction for quantitative analysis by gas chromatography

被引:38
作者
Ouyang, GF
Chen, Y
Setkova, L
Pawliszyn, J
机构
[1] Univ Waterloo, Fac Sci, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Sun Yat Sen Univ, Sch Chem & Chem Engn, Guangzhou 510275, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
calibration; solid-phase microextraction; gas chromatography; liquid injection; SPME fiber injection; sample transfer efficiency; direct injection (DI) liner; SPME liner;
D O I
10.1016/j.chroma.2005.08.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Calibration of SPME by the injection of liquid standard solution is a common method for SPME quantitative analysis by gas chromatography. The feasibility of this calibration method relies on the assumption that sample transfer efficiencies are the same for both the liquid injection and the SPME fiber injection. Sample transfer efficiencies for liquid injection and SPME fiber injection were studied in this paper. The results showed that the sample transfer efficiency for liquid injection was affected by several factors, such as the dimensions of the liner, the presence of the wool, and the temperature of the injector. The sample transfer efficiency for SPME fiber injection was affected by the cross-sectional area of the space between the column and the liner, the carrier gas flow rate, and the length of the column inside the liner. An equation was proposed to estimate the sample loss rate for SPME injection. It was found that the use of a direct injection (DI) liner and program temperature vaporizing provides high sample transfer efficiencies, for both liquid injection and SPME fiber injection. When a common SPME straight liner is used, large outer diameter (o.d.) pre-column will help to achieve high sample transfer efficiency. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 26 条
[1]   Headspace solid phase microextraction. Dynamics and quantitative analysis before reaching a partition equilibrium [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3260-3266
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]   Calibration for on-site analysis of hydrocarbons in aqueous and gaseous samples using solid-phase microextraction [J].
Chen, Y ;
Koziel, JA ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6485-6493
[4]   Time-weighted average passive sampling with a solid-phase microextraction device [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2004-2010
[5]  
CHEPPERWERCINSK.SA, 1999, SOLID PHASE MICROEXT
[6]   Determination of odorous mixed chloro-bromoanisoles in water by solid-phase micro-extraction and gas chromatography-mass detection [J].
Díaz, A ;
Ventura, F ;
Galceran, T .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (01) :97-106
[7]  
GEBHART JE, 1985, ANAL CHEM, V57, P2458, DOI 10.1021/ac00290a008
[8]   SAMPLE INTRODUCTION APPROACHES FOR SOLID-PHASE MICROEXTRACTION RAPID GC [J].
GORECKI, T ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3265-3274
[9]   PEAK BROADENING OR SPLITTING CAUSED BY SOLVENT FLOODING AFTER SPLITLESS OR COLD ON-COLUMN INJECTION IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1981, 213 (01) :3-14
[10]   EFFECT OF DIRT ON QUANTITATIVE-ANALYSES BY CAPILLARY GAS-CHROMATOGRAPHY WITH SPLITLESS INJECTION [J].
GROB, K ;
BOSSARD, M .
JOURNAL OF CHROMATOGRAPHY, 1984, 294 (JUN) :65-75