Impact of 2 different levels of performance feedback on compliance with infection control process measures in 2 intensive care units

被引:29
作者
Assanasen, Susan [1 ,2 ]
Edmond, Michael [2 ]
Bearman, Gonzalo [2 ]
机构
[1] Mahidol Univ, Div Infect Dis & Trop Med, Dept Med, Fac Med,Sriraj Hosp, Bangkok 10700, Thailand
[2] Virginia Commonwealth Univ, Div Infect Dis & Qual Hlth Care, Dept Internal Med, Richmond, VA USA
关键词
D O I
10.1016/j.ajic.2007.08.008
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Performance monitoring and feedback of infection control process measures is an important tool for improving guideline adherence. Different feedback strategies may lead to distinctive outcomes. Objectives: Our objective was to determine the relative impact of 2 different levels of feedback on compliance in an intensive care unit (ICU) setting. Methods: Proportion of head of bed (HOB) elevation, hand hygiene (HH) compliance, and proportion of femoral catheter (FC) to all central venous catheter-days were observed in a medical ICU and a surgical ICU. After a 3-month baseline observation phase (phase 1; P1), we provided quarterly feedback on these process measures and major health care-associated infections (HAIs) to unit leaders from July 2004 to June 2005 (P2). From July 2005 to June 2006 (P3), feedback parameters were also provided to unit leaders and to all staff via 48 X 72-inch color posters in ICU personnel-only areas. At the end of the study, a survey was performed to assess the influence of the posters and HH observations. Results: The analysis of IC process measures included 6948 HOB elevation observations, 1576 HH opportunities, and 16,591 catheter-days. In P2, the overall compliance with HOB elevation and the proportion of FC use significantly improved from 51 % to 88 % (P < .001) and 13% to 7% (P < .001), respectively. No significant difference in HH compliance was observed during this phase (40% vs 47%, respectively; P = .28). Comparing P3 with P2, HH compliance significantly improved from 47% to 71 % (P < 001), and there was a slight improvement in HOB elevation rate from 88% to 93% (P < .001). There was no significant change in FC use in P3. There were 53 survey respondents. Sixty percent reported that the poster information changed their practices. Nearly all respondents (92%) knew that their HH behavior was being observed; however, 61 % claimed that HH compliance was not influenced by observation. Conclusion: Feedback of infection control process measures and major HAIs to unit leadership significantly improved compliance with HOB elevation rate and FC use but not HH. Multilevel feedback significantly improved HH compliance and delivered a satisfactory level of compliance with HOB and FC use in both ICUs during the study period.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 2006, Cochrane Database of Syst Rev, DOI DOI 10.1002/14651858.CD000259.PUB2
[2]   Measurement and feedback of infection control process measures in the intensive care unit: Impact on compliance [J].
Berhe, Mezgebe ;
Edmond, Michael B. ;
Bearman, Gonzalo .
AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (08) :537-539
[3]   National Nosocomial Infections Surveillance (NNIS) System Report, data summary from January 1992 through June 2004, issued October 2004 [J].
Cardo, D ;
Horan, T ;
Andrus, M ;
Dembinski, M ;
Edwards, J ;
Peavy, G ;
Tolson, J ;
Wagner, D .
AMERICAN JOURNAL OF INFECTION CONTROL, 2004, 32 (08) :470-485
[4]   Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients:: a randomised trial [J].
Drakulovic, MB ;
Torres, A ;
Bauer, TT ;
Nicolas, JM ;
Nogué, S ;
Ferrer, N .
LANCET, 1999, 354 (9193) :1851-1858
[5]  
Lipkus I M, 1999, J Natl Cancer Inst Monogr, P149
[6]   Complications of femoral and subclavian venous catheterization in critically ill patients - A randomized controlled trial [J].
Merrer, J ;
De Jonghe, B ;
Golliot, F ;
Lefrant, JY ;
Raffy, B ;
Barre, E ;
Rigaud, JP ;
Casciani, D ;
Misset, B ;
Bosquet, C ;
Outin, H ;
Brun-Buisson, C ;
Nitenberg, G .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (06) :700-707
[7]   The effectiveness of interventions aimed at increasing handwashing in healthcare workers - a systematic review [J].
Naikoba, S ;
Hayward, A .
JOURNAL OF HOSPITAL INFECTION, 2001, 47 (03) :173-180
[8]   Guidelines for the prevention of intravascular catheter-related infections [J].
O'Grady, NP ;
Alexander, M ;
Dellinger, EP ;
Gerberding, JL ;
Heard, SO ;
Maki, DG ;
Masur, H ;
McCormick, RD ;
Mermel, LA ;
Pearson, ML ;
Raad, II ;
Randolph, A ;
Weinstein, RA .
CLINICAL INFECTIOUS DISEASES, 2002, 35 (11) :1281-1307
[9]   Provider education to promote implementation of clinical practice guidelines [J].
Ockene, JK ;
Zapka, JG .
CHEST, 2000, 118 (02) :33S-39S
[10]   Effectiveness of a hospital-wide programme to improve compliance with hand hygiene [J].
Pittet, D ;
Hugonnet, S ;
Harbarth, S ;
Mourouga, P ;
Sauvan, V ;
Touveneau, S ;
Perneger, TV .
LANCET, 2000, 356 (9238) :1307-1312