Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995

被引:102
作者
Torchiana, DF
Hirsch, G
Buckley, MJ
Hahn, C
Allyn, JW
Akins, CW
Drake, JF
Newell, JB
Austen, WG
机构
[1] Massachusetts General Hospital, Boston
关键词
D O I
10.1016/S0022-5223(97)70235-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: A total of 4756 cases of intraaortic balloon pump support have been recorded at the Massachusetts General Hospital since the first clinical insertion for cardiogenic shock in 1968. This report describes the patterns of intraaortic balloon use and associated outcomes over this time period. Methods: A retrospective record review was conducted. Results: Balloon use has increased to more than 300 cases a year at present. The practice of balloon placement for control of ischemia (2453 cases, 11.9% mortality) has become more frequent, whereas support for hemodynamic decompensation (congestive heart failure, hypotension, cardiogenic shock) has been relatively constant (1760 cases, 38.2% mortality). Mean patient age has increased from 54 to 66 years, and mortality has fallen from 41% to 20%. Sixty-five percent (3097/4756) of the total patient population receiving balloon support underwent cardiac surgery. Placement before the operation (2038 patients) was associated with a lower mortality (13.6%) than intraoperative (771 patients, 35.7% mortality) or postoperative use (276 patients, 35.9% mortality). Independent predictors of death with balloon pump support were insertion in the operating room or intensive care unit, transthoracic insertion, age, procedure other than angioplasty or coronary artery bypass, and insertion for cardiogenic shock. Independent predictors of death with intraoperative balloon insertion were age, mitral valve replacement, prolonged cardiopulmonary bypass, urgent or emergency operation, preoperative renal dysfunction, complex ventricular ectopy, right ventricular failure, and emergency reinstitution of cardiopulmonary bypass. Conclusions: Balloons are being used more frequently for control of ischemia in more patients who are elderly with lower mortality. An institutional bias toward preoperative use of the balloon pump appears to be associated with improved outcomes.
引用
收藏
页码:758 / 769
页数:12
相关论文
共 22 条
[1]   A MODEL TO PREDICT SURVIVAL AT TIME OF POSTCARDIOTOMY INTRAAORTIC BALLOON PUMP INSERTION [J].
BALDWIN, RT ;
SLOGOFF, S ;
NOON, GP ;
SEKELA, M ;
FRAZIER, OH ;
EDELMAN, SK ;
VAUGHN, WK .
ANNALS OF THORACIC SURGERY, 1993, 55 (04) :908-913
[2]   VASCULAR COMPLICATIONS FROM INTRAAORTIC BALLOONS - RISK ANALYSIS [J].
BARNETT, MG ;
SWARTZ, MT ;
PETERSON, GJ ;
NAUNHEIM, KS ;
PENNINGTON, DG ;
VACA, KJ ;
FIORE, AC ;
MCBRIDE, LR ;
PEIGH, P ;
WILLMAN, VL ;
KAISER, GC .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (01) :81-89
[3]  
BOLOOKI H, 1984, CLIN APPLICATION INT, P57
[4]   Predicting clinical states in individual patients [J].
Braitman, LE ;
Davidoff, F .
ANNALS OF INTERNAL MEDICINE, 1996, 125 (05) :406-412
[5]   PERCUTANEOUS INTRA-AORTIC BALLOON INSERTION [J].
BREGMAN, D ;
NICHOLS, AB ;
WEISS, MB ;
POWERS, ER ;
MARTIN, EC ;
CASARELLA, WJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 46 (02) :261-264
[6]  
BUCKLEY MJ, 1972, CIRCULATION, V46, P76
[7]  
BUCKLEY MJ, 1970, CIRCULATION S2, V41, P130
[8]  
CLAUSS RH, 1961, J THORAC CARDIOV SUR, V41, P447
[9]   THE RISK OF DETERMINING RISK WITH MULTIVARIABLE MODELS [J].
CONCATO, J ;
FEINSTEIN, AR ;
HOLFORD, TR .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (03) :201-210
[10]   INTRAAORTIC BALLOON COUNTERPULSATION - PATTERNS OF USAGE AND OUTCOME IN CARDIAC-SURGERY PATIENTS [J].
CRESWELL, LL ;
ROSENBLOOM, M ;
COX, JL ;
FERGUSON, TB ;
KOUCHOUKOS, NT ;
SPRAY, TL ;
PASQUE, MK ;
FERGUSON, TB ;
WAREING, TH ;
HUDDLESTON, CB ;
BOLOOKI, H ;
AKINS, CW ;
ROBICSEK, F ;
JACOBEY, JA .
ANNALS OF THORACIC SURGERY, 1992, 54 (01) :11-20