Filtered backprojection for modifying the impulse response of circular tomosynthesis

被引:67
作者
Stevens, GM [1 ]
Fahrig, R
Pelc, NJ
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Appl Phys, Stanford, CA 94305 USA
关键词
tomosynthesis; reconstruction; filtering;
D O I
10.1118/1.1350588
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A filtering technique has been developed to modify the three-dimensional impulse response of circular motion tomosynthesis to allow the generation of images whose appearance is like those of some other imaging geometries. In particular, this technique can reconstruct images with a blurring function which is more homogeneous for off-focal plane objects than that from circular tomosynthesis. In this paper, we describe the filtering process, and demonstrate the ability to alter the impulse response in circular motion tomosynthesis from a ring to a disk. This filtering may be desirable because the blurred out-of-plane objects appear less structured. (C) 2001 American Association of Physicists in Medicine. [DOI: 10.1118/1.1350588].
引用
收藏
页码:372 / 380
页数:9
相关论文
共 11 条
[1]  
[Anonymous], 1983, Medical Imaging Systems
[2]   A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis [J].
Badea, C ;
Kolitsi, Z ;
Pallikarakis, N .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22 (04) :309-315
[3]  
CARTER S J, 1963, Clin Radiol, V14, P405, DOI 10.1016/S0009-9260(63)80029-X
[5]   A theoretical framework for filtered backprojection in tomosynthesis [J].
Lauritsch, G ;
Harer, WH .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :1127-1137
[6]   LINEAR VS PLURIDIRECTIONAL TOMOGRAPHY OF THE CHEST - CORRELATIVE RADIOGRAPHIC ANATOMIC STUDY [J].
LITTLETON, JT ;
DURIZCH, ML ;
CALLAHAN, WP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (02) :241-248
[7]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[8]  
PAPOULIS A, 1991, PROBABILITY RANDOM V, P385
[9]  
PELC N, 1979, THESIS HARVARD U BOS
[10]   SELECTIVE PLANE REMOVAL IN LIMITED ANGLE TOMOGRAPHIC IMAGING [J].
ROY, DNG ;
KRUGER, RA ;
YIH, B ;
DELRIO, P .
MEDICAL PHYSICS, 1985, 12 (01) :65-70