Barbed micro-spikes for micro-scale biopsy

被引:28
作者
Byun, S [1 ]
Lim, JM
Paik, SJ
Lee, A
Koo, K
Park, S
Park, J
Choi, BD
Seo, JM
Kim, K
Chung, H
Song, SY
Jeon, D
Cho, D
机构
[1] Seoul Natl Univ, Sch Elect Engn & Comp Sci, ERC NBS, ISRC,ASRI, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Seoul Artificial Eye Ctr, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Dept Internal Med, Seoul 120749, South Korea
[5] Sogang Univ, Dept Engn Mech, Seoul, South Korea
关键词
D O I
10.1088/0960-1317/15/6/020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 gm thick and 250 gm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.
引用
收藏
页码:1279 / 1284
页数:6
相关论文
共 19 条
[1]   Characterization of surface micromachined metallic microneedles [J].
Chandrasekaran, S ;
Frazier, AB .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (03) :289-295
[2]  
CHUNG H, 2004, ASS RES VIS OPTH ANN
[3]   Colonic perforation with endoscopic biopsy [J].
Eckardt, VF ;
Gaedertz, C ;
Eidner, C .
GASTROINTESTINAL ENDOSCOPY, 1997, 46 (06) :560-562
[4]   A BioMEMS review: MEMS technology for physiologically integrated devices [J].
Grayson, ACR ;
Shawgo, RS ;
Johnson, AM ;
Flynn, NT ;
Li, YW ;
Cima, MJ ;
Langer, R .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :6-21
[5]  
HILL D, 1998, DESIGN ENG BIOMATERI
[6]  
Kim J, 2001, TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P662
[7]  
KRULEVITCH PA, 1999, Patent No. 5928161
[8]  
KRULEVITCH PA, 1999, Patent No. 5985217
[9]  
Lee A. P., 1995, 8th International Conference on Solid-State Sensors and Actuators and Eurosensors IX. Digest of Technical Papers (IEEE Cat. No.95TH8173), P368
[10]  
LIM JM, 2004, 6 KOR MEMS C CHEJ 8, P287