Ultimate tensile failure loads of a human dermal allograft rotator cuff augmentation

被引:100
作者
Barber, F. Alan [1 ]
Herbert, Morley A. [2 ]
Boothby, Michael H. [3 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
[2] Med City Dallas Hosp, Adv Surg Inst, Dallas, TX USA
[3] SW Orthoped, Ft Worth, TX USA
关键词
GraftJacket; rotator cuff; arthroscopy; augmentation patches; biomechanical testing; shoulder;
D O I
10.1016/j.arthro.2007.07.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to examine the failure mode of supraspinatus tendon repairs with and without human dermal allograft augmentation. Methods: Ten matched pairs of human cadaveric supraspinatus muscles and tendons were detached from their greater tuberosity insertions and then reattached with four simple sutures in 2 suture anchors as a control group. One shoulder from each matched pair was augmented with human dermal allograft secured to the humerus and the supraspinatus tendon using the same sutures and suture anchors. Additional interrupted mattress sutures secured the edges of the dermal allograft to the supraspinatus tendon. Each construct was preloaded at 10 N and then cyclically loaded between 10 N and 100 N for 10 cycles at 20 N/s followed by destructive testing at 33 mm/s. Force and displacement were recorded. Results: The mean failure strengths for the control and augmented constructs were 273 +/- 116 N and 325 +/- 74 N, respectively (P = .047). No significant displacement occurred during the cyclic phase, and no anchors failed. These constructs failed by 2 different mechanisms: tendon-suture interface failure (8/10 non-augmented repairs and 6/10 augmented repairs) and suture breakage (2/10 non-augmented repairs and 4/10 augmented repairs). Conclusions: This examination of the failure characteristics and ultimate failure load of supraspinatus tendon tears augmented with GraftJacket (Wright Medical Technology, Arlington, TN) supported the study hypothesis that a human dermal allograft significantly increases the strength of a repaired tendon. Clinical Relevance: The human dermal allograft can be expected to significantly increase the initial strength of a rotator cuff repair.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 28 条
[1]
Rotator cuff repair using an acellular dermal matrix graft: An in vivo study in a canine model [J].
Adams, Julie E. ;
Zobitz, Mark E. ;
Reach, John S., Jr. ;
an, Kai-N An ;
Steinmann, Scott P. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (07) :700-709
[2]
Sutures and suture anchors - Update 2006 [J].
Barber, F. Alan ;
Herbert, Morley A. ;
Coons, David A. ;
Boothby, Michael H. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (10) :1063-1069
[3]
Tendon augmentation grafts: Biomechanical failure loads and failure patterns [J].
Barber, F. Alan ;
Herbert, Morley A. ;
Coons, David A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05) :534-538
[4]
Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[5]
Evaluation of residual rotator cuff defects after in vivo single- versus double-row rotator cuff repairs [J].
Brady, Paul C. ;
Arrigoni, Paolo ;
Burkhart, Stephen S. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (10) :1070-1075
[6]
Complications after arthroscopic rotator cuff repair [J].
Brislin, Kenneth J. ;
Field, Larry D. ;
Savoie, Felix H., III .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (02) :124-128
[7]
Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation [J].
Burkhart, SS ;
Pagan, JLD ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (06) :720-724
[8]
Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[9]
Burkhead WZ., 2007, SEMIN ARTHOPLASTY, P11, DOI DOI 10.1053/J.SART.2006.11.017
[10]
Surgical repair of chronic rotator cuff tears - A prospective long-term study [J].
Cofield, RH ;
Parvizi, J ;
Hoffmeyer, PJ ;
Lanzer, WL ;
Ilstrup, DM ;
Rowland, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (01) :71-77