Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique

被引:154
作者
Nieponice, Alejandro [1 ,4 ]
Soletti, Lorenzo [1 ,2 ,4 ]
Guan, Jianjun [1 ,4 ]
Deasy, Bridget M. [2 ,3 ,4 ]
Huard, Johnny [2 ,3 ,4 ]
Wagner, Williarn R. [1 ,2 ,4 ]
Vorp, David A. [1 ,2 ,4 ]
机构
[1] Univ Pittsburgh, Dept Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[4] McGowan Inst Regenerat Med, Pittsburgh, PA USA
关键词
vascular tissue engineering; muscle-derived stem cells; scaffolds; vascular grafts; cell seeding; dynamic culture;
D O I
10.1016/j.biomaterials.2007.10.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is a clinical need for a tissue-engineered vascular graft (TEVG), and combining stem cells with biodegradable tubular scaffolds appears to be a promising approach. The goal of this study was to characterize the incorporation of muscle-derived stem cells (MDSCs) within tubular poly(ester urethane) urea (PEUU) scaffolds in vitro to understand their interaction, and to evaluate the mechanical properties of the constructs for vascular applications. Porous PEUU scaffolds were seeded with MDSCs using our recently described rotational vacuum seeding device, and cultured inside a spinner flask for 3 or 7 days. Cell viability, number, distribution and phenotype were assessed along with the suture retention strength and uniaxial mechanical behavior of the TEVGs. The seeding device allowed rapid even distribution of cells within the scaffolds. After 3 days, the constructs appeared completely populated with cells that were spread within the polymer. Cells underwent a population doubling of 2.1-fold, with a population doubling time of 35h. Stem cell antigen-1 (Sca-1) expression by the cells remained high after 7 days in culture (77 +/- 20% vs. 66 +/- 6% Lit day 0) while CD34 expression was reduced (19 +/- 12% vs. 61 +/- 10% at day 0) and myosin heavy chain expression was scarce (not quantified). The estimated burst strength of the TEVG constructs was 2127 +/- 900mmHg and suture retention strength was 1.3 +/- 0.3 N. We conclude from this study that MDSCs can be rapidly seeded within porous biodegradable tubular scaffolds while maintaining cell viability and high proliferation rates and without losing stem cell phenotype for tip to 7 days of in-vitro Culture. The successful integration of these steps is thought necessary to provide rapid availability of TEVGs, which is essential for clinical translation. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:825 / 833
页数:9
相关论文
共 72 条
[1]  
[Anonymous], [No title captured]
[2]  
[Anonymous], 2004, HEART DIS STROK STAT
[3]   Adult skeletal muscle stem cells differentiate into endothelial lineage and ameliorate renal dysfunction after acute ischemia [J].
Arriero, M ;
Brodsky, SV ;
Gealekman, O ;
Lucas, PA ;
Goligorsky, MS .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2004, 287 (04) :F621-F627
[4]   Chondrogenic differentiation of mesenchymal stem cells from bone marrow: Differentiation-dependent gene expression of matrix components [J].
Barry, F ;
Boynton, RE ;
Liu, BS ;
Murphy, JM .
EXPERIMENTAL CELL RESEARCH, 2001, 268 (02) :189-200
[5]   Expression of CD34 and Myf5 defines the majority of quiescent adult skeletal muscle satellite cells [J].
Beauchamp, JR ;
Heslop, L ;
Yu, DSW ;
Tajbakhsh, S ;
Kelly, RG ;
Wernig, A ;
Buckingham, ME ;
Partridge, TA ;
Zammit, PS .
JOURNAL OF CELL BIOLOGY, 2000, 151 (06) :1221-1233
[6]  
BONANNO E, 1994, LAB INVEST, V71, P308
[7]   Molecular signaling in bioengineered tissue microenvironments [J].
Bottaro, DP ;
Liebmann-Vinson, A ;
Heidaran, MA .
REPARATIVE MEDICINE: GROWING TISSUES AND ORGANS, 2002, 961 :143-153
[8]   Electrostatic endothelial cell transplantation within small-diameter (<6 mm) vascular prostheses:: A prototype apparatus and procedure [J].
Bowlin, GL ;
Rittgers, SE .
CELL TRANSPLANTATION, 1997, 6 (06) :631-637
[9]   Infarct remodeling after intracoronary progenitor cell treatment in patients with acute myocardial infarction (TOPCARE-AMI) -: Mechanistic insights from serial contrast-enhanced magnetic resonance imaging [J].
Britten, MB ;
Abolmaali, ND ;
Assmus, B ;
Lehmann, R ;
Honold, J ;
Schmitt, J ;
Vogl, TJ ;
Martin, H ;
Schächinger, V ;
Dimmeler, S ;
Zeiher, AM .
CIRCULATION, 2003, 108 (18) :2212-2218
[10]  
Burg KJL, 2000, J BIOMED MATER RES, V51, P642, DOI 10.1002/1097-4636(20000915)51:4<642::AID-JBM12>3.0.CO