Assessment of body composition in elderly:: Accuracy of bioelectrical impedance analysis

被引:47
作者
Bussolotto, M [1 ]
Ceccon, A [1 ]
Sergi, G [1 ]
Giantin, V [1 ]
Benincà, P [1 ]
Enzi, G [1 ]
机构
[1] Univ Padua, Div Geriatr, Dept Internal Med, Padua, Italy
关键词
body composition; elderly; bioelectrical impedance analysis; dual photon absorptiometry;
D O I
10.1159/000022053
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: In the literature there are several body impedance analysis (BIA) prediction equations generally determined in younger populations and their accuracy in the elderly has not been adequately confirmed. Objective: We verified the reliability of the BIA method in a body composition study in the elderly. Methods:To assess the accuracy of bioelectrical impedance analysis we compared this method with dual photon absorptiometry (DPA), assumed as a gold standard; body composition was predicted by seven BIA prediction equations in 24 healthy elderly individuals. Results:The best equation in fat-free mass (FFM) estimation is the RJL System formula (published by Segal in 1988); nevertheless, the wide range of the error in FFM estimating may limit its clinical application. The FFM hydration variability seems to be the principal variable which explains the error in FFM estimation by BIA prediction equations. Conclusion: These findings indicate that the use of BIA equations is not interchangeable, when FFM is calculated in an elderly population, and more validation studies are necessary in this age group to evaluate the clinical application of this method.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 34 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BORKAN GA, 1977, HUM BIOL, V49, P495
[3]  
BOSAEUS I, 1991, NUTRITIONAL STATUS A, P63
[4]   MEASUREMENT OF BODY-COMPOSITION IN THE ELDERLY - DUAL-ENERGY X-RAY ABSORPTIOMETRY, UNDERWATER WEIGHING, BIOELECTRICAL-IMPEDANCE ANALYSIS, AND ANTHROPOMETRY [J].
BRODOWICZ, GR ;
MANSFIELD, RA ;
MCCLUNG, MR ;
ALTHOFF, SA .
GERONTOLOGY, 1994, 40 (06) :332-339
[5]   TOTAL-BODY WATER AND EXCHANGEABLE HYDROGEN .1. THEORETICAL CALCULATION OF NON-AQUEOUS EXCHANGEABLE HYDROGEN IN MAN [J].
CULEBRAS, JM ;
MOORE, FD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (01) :R54-R59
[6]  
DEURENBERG P, 1989, EUR J CLIN NUTR, V43, P569
[7]   ASSESSMENT OF BODY-COMPOSITION BY BIOELECTRICAL IMPEDANCE IN A POPULATION AGED GREATER-THAN-60-Y [J].
DEURENBERG, P ;
VANDERKOOIJ, K ;
EVERS, P ;
HULSHOF, T .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (01) :3-6
[8]   BODY FAT ASSESSED FROM TOTAL-BODY DENSITY AND ITS ESTIMATION FROM SKINFOLD THICKNESS - MEASUREMENTS ON 481 MEN AND WOMEN AGED FROM 16 TO 72 YEARS [J].
DURNIN, JVGA ;
WOMERSLEY, J .
BRITISH JOURNAL OF NUTRITION, 1974, 32 (01) :77-97
[9]  
FORBES G, 1988, HUMAN BODY COMPOSITI
[10]  
FORBES GB, 1976, HUM BIOL, V48, P161