Optimizing liver contrast in helical liver CT:: value of a real-time bolus-triggering technique

被引:30
作者
Dinkel, HP [1 ]
Fieger, M [1 ]
Knüpffer, J [1 ]
Moll, R [1 ]
Schindler, G [1 ]
机构
[1] Univ Wurzburg, Dept Diagnost Radiol, D-97080 Wurzburg, Germany
关键词
liver CT; contrast enhancement; Bolus triggering;
D O I
10.1007/s003300050596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Optimal liver enhancement during portal venous-phase helical CT is crucial in the detection of parenchymal liver lesions. In the prospective study reported here we investigated the effects of a real-time bonus-tracking system on mean and maximal liver enhancement. In 79 patients referred to us for abdominal CT we injected 120 ml of non-ionic contrast (300 mg I/ml) at a rate of 3 ml/s. After a nonintravenous contrast upper abdominal scan a portal venous phase was performed. In 39 patients (mean weight 72.6 +/- 18.7 kg, range 48-139 kg) real-time bolus tracking was performed using the CARE Bolus software (Siemens, Erlangen, Germany). The software performs repetitive low-dose test scans in a preselected region of interest and measures the Hounsfield attenuation and liver enhancement in real-time. After a critical threshold (we selected 31 HU) is surpassed, the software starts diagnostic spiral scanning. Our control consisted of 40 patients weighing 51-100 kg (mean 73.2 +/- 11.1 kg) who were scanned with a fixed, preselected start delay or 80 s. Mean hepatic enhancement was 54.0 +/- 9.9 HU (range 33.3-74 HU) in 37 automatically triggered patients peak hepatic enhancement 64.6 +/- 12.6 HU (range 42.0-91.8 HU). In 2 patients of the study group scanning had to be started manually. In the control group with fixed delay mean enhancement was 48.3 +/- 9.2 HU (range 33.8-71.6 HU) and peak enhancement 55.5 +/- 9.7 HU (range 39.7-81.0 HU). Differences were significant (p < 0.05, Student's t-test). Real-time bolus tracking significantly increased mean hepatic enhancement and may improve portal venous hepatic CT scanning.
引用
收藏
页码:1608 / 1612
页数:5
相关论文
共 21 条
  • [1] COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY
    BERLAND, LL
    LEE, JY
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (12) : 918 - 922
  • [2] CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION
    BURGENER, FA
    HAMLIN, DJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) : 351 - 358
  • [3] Claussen C D, 1982, Rofo, V137, P212, DOI 10.1055/s-2008-1056187
  • [4] BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION
    CLAUSSEN, CD
    BANZER, D
    PFRETZSCHNER, C
    KALENDER, WA
    SCHORNER, W
    [J]. RADIOLOGY, 1984, 153 (02) : 365 - 368
  • [5] DINKEL HP, 1997, AJR S3, V168, P332
  • [6] DINKEL HP, 1997, EUR RADIOL, V7, P794
  • [7] FOLEY DW, 1996, ANN M AM ROENT RAY S, P1
  • [8] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [9] BOLUS-TRIGGERED SPIRAL CT - A NEW PROGRAM-MONITORED METHOD FOR OPTIMAL CONTRAST
    FUNKE, M
    KOPKA, L
    VOSSHENRICH, R
    OESTMANN, JW
    GRABBE, E
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (04): : 335 - 337
  • [10] RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY
    GALANSKI, M
    PROKOP, M
    CHAVAN, A
    SCHAEFER, CM
    JANDELEIT, K
    NISCHELSKY, JE
    [J]. RADIOLOGY, 1993, 189 (01) : 185 - 192