Volume of blood required to detect common neonatal pathogens

被引:281
作者
Schelonka, RL
Chai, MK
Yoder, BA
Hensley, D
Brockett, RM
Ascher, DP
机构
[1] WILFORD HALL USAF MED CTR, DIV NEONATOL, LACKLAND AFB, TX USA
[2] WILFORD HALL USAF MED CTR, DIV PATHOL, LACKLAND AFB, TX USA
关键词
D O I
10.1016/S0022-3476(96)70254-8
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To determine the minimum volume of blood and the absolute number of organisms required for detection of bacteremia and fungemia by an automated colorimetric blood culture system (BacT/Alert, Organon Teknika). Design: Common neonatal pathogens, Escherichia coli, Streptococcus agalactiae (group B streptococcus (GBS): one American Type Culture Collection (ATCC) strain and one clinical isolate), Staphylococcus epidermidis, and Candida albicans, were seeded into blood to produce bacteremia or fungemia with low colony counts (1 to 3 colony-forming units (CFU) per milliliter) and ultra-low colony counts (<1 CFU/ml). For each organism, 96 culture bottles were inoculated with either 0.25, 0.5, 1.0, or 4.0 mi of the two seeded blood concentrations. Blood culture bottles were incubated in the BacT/Alert device for 5 days, and time to positivity was noted when applicable. All bottles were subcultured on plated media. Data analysis: The Poisson statistic was used to calculate the probability of finding at least one viable CFU per inoculated culture bottle. The fraction of culture bottles with positive findings per group was divided by the probability of one or more organisms present to give the positivity index. Results: Plated subculture identified no growth of organisms not detected by the colorimetric detection system. The false-positive rate for the automated device was less than 1%. The positivity index for the GBS clinical isolate was 1.13, for the GBS ATCC isolate 0.96, for S. epidermidis 0.94, for C. albicans 0.97, and for E. coli 0.95. There was a statistically significant difference with time to positivity and inocula volume (p < 0.01), but the difference was not clinically important. Conclusions: If one or two viable colony-forming units are in the blood inoculated into culture media, the BacT/Alert system will detect growth rapidly, Because there appears to be a sizable subset of neonates who are at risk of sepsis with a colony count less than 4 CFU/ml, then a 0.5 mi inoculum of blood into the culture media is inadequate for sensitive and timely detection of bacteremia. One to two milliliters of blood should increase microorganism recovery in the face of low-colony-count sepsis.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 28 条
[1]  
BARTLETT RC, 1974, CUMITECH, V1
[2]   NEONATAL ESCHERICHIA-COLI SEPTICEMIA BACTERIAL COUNTS IN BLOOD [J].
DIETZMAN, DE ;
FISCHER, GW ;
SCHOENKNECHT, FD .
JOURNAL OF PEDIATRICS, 1974, 85 (01) :128-130
[3]   QUANTITATIVE BLOOD CULTURES IN CHILDHOOD BACTEREMIA [J].
DURBIN, WA ;
SZYMCZAK, EG ;
GOLDMANN, DA .
JOURNAL OF PEDIATRICS, 1978, 92 (05) :778-780
[4]   TIME TO DETECTION OF POSITIVE BACT ALERT BLOOD CULTURES AND LACK OF NEED FOR ROUTINE SUBCULTURE OF 5-DAY TO 7-DAY NEGATIVE CULTURES [J].
HARDY, DJ ;
HULBERT, BB ;
MIGNEAULT, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (10) :2743-2745
[5]   THE IMPORTANCE OF VOLUME OF BLOOD CULTURED IN THE DETECTION OF BACTEREMIA AND FUNGEMIA [J].
ILSTRUP, DM ;
WASHINGTON, JA .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1983, 1 (02) :107-110
[6]   Effect of number of blood cultures and volume of blood on detection of bacteremia in children [J].
Isaacman, D ;
Karasic, RB ;
Reynolds, EA ;
Kost, SI .
JOURNAL OF PEDIATRICS, 1996, 128 (02) :190-195
[7]   SEPTIC SHOCK IN CHILDREN - BACTERIAL ETIOLOGIES AND TEMPORAL RELATIONSHIPS [J].
JACOBS, RF ;
SOWELL, MK ;
MOSS, MM ;
FISER, DH .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1990, 9 (03) :196-200
[8]  
KNUDSON RP, 1980, PEDIATRICS, V65, P505
[9]   COMPARISON OF THE BACT ALERT PEDIATRIC BLOOD CULTURE SYSTEM, PEDI-BACT, WITH CONVENTIONAL CULTURE USING THE 20-MILLILITER BECTON-DICKINSON SUPPLEMENTED PEPTONE BROTH TUBE [J].
KRISHER, KK ;
WHYBURN, DR ;
KOEPNICK, FE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (04) :793-797
[10]   EFFECTS OF VOLUME AND PERIODICITY ON BLOOD CULTURES [J].
LI, J ;
PLORDE, JJ ;
CARLSON, LG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (11) :2829-2831