Phase-inversion sonography during the liver-specific late phase of contrast enhancement: Improved detection of liver metastases

被引:115
作者
Albrecht, T
Hoffmann, CW
Schmitz, SA
Schettler, S
Overberg, A
Germer, CT
Wolf, KJ
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Radiol & Nucl Med, D-12200 Berlin, Germany
[2] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Surg, D-12200 Berlin, Germany
关键词
D O I
10.2214/ajr.176.5.1761191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to assess whether phase-inversion sonography during the late, liver-specific phase of contrast enhancement using Levovist improves the detection of hepatic metastases relative to unenhanced conventional B-mods sonography. SUBJECTS AND METHODS. Sixty-two patients were studied with unenhanced B-mode sonography and phase-inversion sonography 2.5 min after the injection of Levovist. All patients underwent one reference examination (CT, MR imaging, or intraoperative sonography). The conspicuity, number, size, and distribution of metastases before and after contrast administration as judged by a sonographer (who was unaware of other imagine findings) were compared with each other and with reference imaging. RESULTS. The conspicuity of metastases was improved by contrast-enhanced phase inversion in 94% of patients. Thirty-nine patients showed metastases on reference imaging; 36 of these were positive on baseline sonography and 38 on phase-inversion sonography, Phase-inversion sonography showed mole reference imaging-confirmed metastases than baseline sonography in 28 patients (45%). The average number of confirmed metastases per patient was 3.06 for baseline sonography and 5.42 for contrast-enhanced phase-inversion sonography (p < 0.01). The average sensitivity for detecting individual metastases improved from 63% to 91%. Metastases of less than 1 cm were shown in 14 patients on baseline sonography, in 24 patients on phase-inversion sonography and in 26 on reference imaging, Both sonographic techniques showed false-positive lesions in six patients. CONCLUSION. Contrast-enhanced phase-inversion sonography in the liver-specific phase of contrast enhancement using Levovist provides a marl;ed improvement in the detection of hepatic metastases relative: to unenhanced conventional sonography, without loss of specificity. Phase-inversion sonography was particularly advantageous in detecting small metastases and may be a competitive alternative to CT and MR imaging.
引用
收藏
页码:1191 / 1198
页数:8
相关论文
共 21 条
[1]   B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: Initial experience in humans [J].
Albrecht, T ;
Hoffmann, CW ;
Schettler, S ;
Overberg, A ;
Ilg, M ;
von Behren, PL ;
Bauer, A ;
Wolf, KJ .
RADIOLOGY, 2000, 216 (01) :273-278
[2]   Stimulated acoustic emission with the ultrasound contrast agent levovist: a clinically useful contrast effect with liver-specific properties [J].
Albrecht, T ;
Blomley, MJK ;
Heckemann, RA ;
Cosgrove, DO ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Hoffmann, CW ;
Bauer, A .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01) :61-67
[3]  
BAUER A, 1997, ADV ECHO IMAGING USI, P669
[4]   Stimulated acoustic emission in liver parenchyma with Levovist [J].
Blomley, M ;
Albrecht, T ;
Cosgrove, D ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, R .
LANCET, 1998, 351 (9102) :568-568
[5]   Stimulated acoustic emission to image a late liver and spleen-specific phase of Levovist® in normal volunteers and patients with and without liver disease [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Eckersley, RJ ;
Butler-Barnes, J ;
Jayaram, V ;
Patel, N ;
Heckemann, RA ;
Bauer, A ;
Schlief, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1341-1352
[6]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[7]  
BLOMLEY MJK, 2001, IN PRESS RADIOLOGY
[8]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[9]  
CLARKE MP, 1989, SURGERY, V106, P849
[10]  
COUINAUD C, 1980, CHIRURGIE, V106, P103