UK audit and analysis of quantitative parameters obtained from gamma camera renography

被引:23
作者
Houston, AS [1 ]
Whalley, DR [1 ]
Skrypniuk, JV [1 ]
Jarritt, PH [1 ]
Fleming, JS [1 ]
Cosgriff, PS [1 ]
机构
[1] Inst Phys & Engn Med, Nucl Med Software Working Party, York, N Yorkshire, England
关键词
gamma camera; renography;
D O I
10.1097/00006231-200105000-00015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to perform an audit of quantitative values obtained from gamma camera renography in the UK. Ten patient image sequences representing normal and pathological renal function were obtained from archived studies and distributed to hospitals in the UK. Hospitals were asked to measure five parameters: relative function, renogram time-to-peak (left and right), and whole kidney mean transit time (left and right). Details of methodology, software used and operator experience were requested. This allowed the influence of operational factors on variations in reported values to be examined. A total of 180 responses from 81 hospitals were received. Values reported for the parameters, together with other details supplied, were entered into Excel and SPSS for statistical analysis. Histograms representing the distribution of values were produced for each parameter. The largest variations were found for mean transit time and occasionally for time-to-peak. The effect of factors was assessed using non-parametric statistical tests applied independently to each renogram. For all the parameters, the hospital, UK region, supplier, computer and software version influenced variations in the reported values. Algorithm and site of background region were influencing factors for relative function, the background subtraction method influenced time-to-peak, and curve smoothing influenced mean transit time. ((C) 2001 Lippincott Williams & Wilkins).
引用
收藏
页码:559 / 566
页数:8
相关论文
共 13 条
[1]   OBSTRUCTIVE NEPHROPATHY - COMPARISON BETWEEN PARENCHYMAL TRANSIT-TIME INDEX AND FRUSEMIDE DIURESIS [J].
BRITTON, KE ;
NAWAZ, MK ;
WHITFIELD, HN ;
NIMMON, CC ;
CARROLL, MJ ;
GRANOWSKA, M ;
MLODKOWSKA, E .
BRITISH JOURNAL OF UROLOGY, 1987, 59 (02) :127-132
[2]  
BRITTON KE, 1980, RADIONUCLIDES NEPHRO, P164
[3]  
CHAIWATANARAT T, 1993, J NUCL MED, V34, P845
[4]   TOWARDS STANDARDIZATION IN GAMMA-CAMERA RENOGRAPHY [J].
COSGRIFF, PS ;
LAWSON, RS ;
NIMMON, CC .
NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (08) :580-585
[5]  
COSGRIFF PS, 1989, NUCL MED COMMUN, V10, P535
[6]   Quality assurance in renography: A review [J].
Cosgriff, PS .
NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (07) :711-716
[7]  
COSGRIFF PS, 1997, 17916EN EUR
[8]   UK audit of relative renal function measurement using DMSA scintigraphy [J].
Fleming, JS ;
Cosgriff, PS ;
Houston, AS ;
Jarritt, PH ;
Skrypniuk, JV ;
Whalley, DR .
NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (10) :989-997
[9]  
LAWSON RS, 1986, NUCLEAR MED UROLOGY, P247
[10]   A MULTIPLE-REGRESSION ANALYSIS FOR ACCURATE BACKGROUND SUBTRACTION IN TC-99M-DTPA RENOGRAPHY [J].
MIDDLETON, GW ;
THOMSON, WH ;
DAVIES, IH ;
MORGAN, A .
NUCLEAR MEDICINE COMMUNICATIONS, 1989, 10 (05) :315-324