Investigation of pleural effusion - An evaluation of the new Olympus LTF semiflexible thoracofiberscope and comparison with Abram's needle biopsy

被引:64
作者
McLean, AN [1 ]
Bicknell, SR
McAlpine, LG
Peacock, AJ
机构
[1] W Glasgow Hosp Univ NGS Trust, Dept Resp Med, Glasgow, Lanark, Scotland
[2] Ayr Hosp, Ayr, Scotland
[3] Monklands Hosp, Airdrie, Scotland
关键词
pleural biopsy; pleural effusion; thoracoscopy;
D O I
10.1378/chest.114.1.150
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: Recently, pulmonologists have performed thoracoscopy under local anesthesia using rigid thoracoscopes or flexible bronchoscopes. The latter allow greater access within the pleural cavity but are difficult to manipulate. The Olympus LTF semiflexible fiberoptic thoracoscope combines features of both instruments, having a solid body and a flexible terminal section. In the first study with this instrument, we evaluated ease of use and compared diagnostic yield with closed needle biopsy. Patients: Twenty-four patients with pleural effusion were investigated Setting: Scottish University Hospital, Design: Thoracoscopy was pet-formed in the bronchoscopy suite after premedication with atropine and papaveretum. Following a standard Abram's needle biopsy, the LTF thoracoscope was inserted through a flexible introducer (Olympus Optical Co Ltd; Tokyo, Japan). The pleura was inspected and biopsy specimens were taken of suspicious areas. Results: The final diagnosis was malignant pleural effusion in 16 of 24 patients. Ten of 16 were positive by Abram's biopsy, giving a sensitivity of 62%. Thirteen of 16 were positive by fiberoptic thoracoscopy, giving an improved sensitivity of 81%. The LTF thoracoscope was easy to use for pulmonologists experienced in rigid thoracoscopy and flexible bronchoscopy. Excellent views of the pleura were obtained from a single entry point, The procedure was well tolerated and no complications were encountered. Conclusion: The LTF thoracoscope allows excellent pleural access but a larger biopsy channel (currently 2 mm) might increase the accuracy of diagnosis.
引用
收藏
页码:150 / 153
页数:4
相关论文
共 11 条
[1]  
BOUTIN C, 1981, AM REV RESPIR DIS, V124, P588
[2]  
BOUTIN C, 1992, PRACTICAL THORACOSCO, P1
[3]  
Boutin C., 1992, PRACTICAL THORACOSCO, P13
[4]   THORACOSCOPY - ASSESSMENT OF A PHYSICIAN SERVICE AND COMPARISON OF A FLEXIBLE BRONCHOSCOPE USED AS A THORACOSCOPE WITH A RIGID THORACOSCOPE [J].
DAVIDSON, AC ;
GEORGE, RJ ;
SHELDON, CD ;
SINHA, G ;
CORRIN, B ;
GEDDES, DM .
THORAX, 1988, 43 (04) :327-332
[5]  
ISAAC FEB, 1975, CHEST, V67, P573
[6]  
LODDENKEMPER R, 1993, EUR RESPIR J, V6, P1544
[7]  
LODDENKEMPER R, 1983, AM REV RESPIR DIS, V127, P114
[8]   CLINICAL UTILITY OF THORACOSCOPY [J].
MATHUR, P ;
MARTIN, WJ .
CHEST, 1992, 102 (01) :2-4
[9]   EFFICACY OF PLEURAL NEEDLE-BIOPSY AND PLEURAL FLUID CYTOPATHOLOGY IN DIAGNOSIS OF MALIGNANT NEOPLASM INVOLVING PLEURA [J].
SALYER, WR ;
EGGLESTON, JC ;
EROZAN, YS .
CHEST, 1975, 67 (05) :536-539
[10]  
SENNO A, 1974, J THORAC CARDIOV SUR, V67, P606