Near-infrared determination of active substance content in intact low-dosage tablets

被引:64
作者
Chalus, P
Roggo, Y
Walter, S
Ulmschneider, M [1 ]
机构
[1] F Hoffmann La Roche & Cie AG, CH-4070 Basel, Switzerland
[2] UHA, GSEC, Mulhouse, France
关键词
near-infrared spectroscopy; active content; intact tablets; content uniformity; pretreatment; regression;
D O I
10.1016/j.talanta.2005.01.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Near-infrared (NIR) spectroscopy can be applied to determine the active substance content of tablets. Its great advantage lies in the minimal sample preparation required, which helps to reduce the potential for error. The aim of this study is to show the feasibility of this method on low-dosage tablets. The influence of various spectral pretreatments [standard normal variate (SNV), multiplicative scatter correction (MSC), second derivative (D2), orthogonal signal correction (OSC), separately and combined] and regression methods on prediction error are compared. Partial least square (PLS) regression provided better prediction than principal component regression (PCR). SNV was applied to the first data set and SNV and a second derivative to the second set to maximise model accuracy for quantifying the active substance of intact pharmaceutical products using diffuse reflectance NIR. The models yielded standard errors of prediction (SEP) of 0.1768 and 0.0682 mg for the two products. The experiments were conducted with two low-dosage pharmaceutical forms and results of NIR predictions were comparable to currently approved methods. Diffuse reflectance NIR has the potential to become a reliable and robust quality control method for determining active tablet content. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1294 / 1302
页数:9
相关论文
共 35 条
[1]  
Adams MJ., 1995, CHEMOMETRICS ANAL SP
[2]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[3]   Characterization and analysis of polymorphs by near-infrared spectrometry [J].
Blanco, M ;
Valdés, D ;
Bayod, MS ;
Fernández-Marí, F ;
Llorente, I .
ANALYTICA CHIMICA ACTA, 2004, 502 (02) :221-227
[4]   Near-infrared analytical control of pharmaceuticals. A single calibration model from mixed phase to coated tablets [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Serrano, D .
ANALYST, 1998, 123 (11) :2307-2312
[5]   Identification and quantitation assays for intact tablets of two related pharmaceutical preparations by reflectance near-infrared spectroscopy:: validation of the procedure [J].
Blanco, M ;
Eustaquio, A ;
González, JM ;
Serrano, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) :139-148
[6]   Strategies for constructing the calibration set in the determination of active principles in pharmaceuticals by near infrared diffuse reflectance spectrometry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
ANALYST, 1997, 122 (08) :761-765
[7]   NIR spectroscopy: a rapid-response analytical tool [J].
Blanco, M ;
Villarroya, I .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (04) :240-250
[8]   Application of transmission near-infrared spectroscopy to uniformity of content testing of intact steroid tablets [J].
Broad, NW ;
Jee, RD ;
Moffat, AC ;
Smith, MR .
ANALYST, 2001, 126 (12) :2207-2211
[9]   The use of near infra-red spectroscopy to detect changes in the form of amorphous and crystalline lactose [J].
Buckton, G ;
Yonemochi, E ;
Hammond, J ;
Moffat, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1998, 168 (02) :231-241
[10]   Prediction of drug content and hardness of intact tablets using artificial neural network and near-infrared spectroscopy [J].
Chen, YX ;
Thosar, SS ;
Forbess, RA ;
Kemper, MS ;
Rubinovitz, RL ;
Shukla, AJ .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2001, 27 (07) :623-631