Simultaneous determination of 13 phytohormones in oilseed rape tissues by liquid chromatography-electrospray tandem mass spectrometry and the evaluation of the matrix effect

被引:50
作者
Fan, Sufang [1 ,2 ,3 ]
Wang, Xiupin [1 ,2 ,3 ]
Li, Peiwu [1 ,2 ,3 ]
Zhang, Qi [1 ,2 ]
Zhang, Wen [1 ,2 ]
机构
[1] Chinese Acad Agr Sci, Oil Crops Res Inst, Wuhan 430062, Peoples R China
[2] Minist Agr, Key Lab Oil Crop Biol, Wuhan, Peoples R China
[3] Minist Agr PRC, Qual Inspect & Test Ctr Oilseeds & Prod, Wuhan, Peoples R China
关键词
Liquid chromatography-tandem mass spectrometry; Matrix effect; Phytohormones; Rape tissues; SOLID-PHASE EXTRACTION; ABSCISIC-ACID; GAS-CHROMATOGRAPHY; PLANT-EXTRACTS; PESTICIDE-RESIDUES; HPLC-MS/MS; PURIFICATION; STANDARD; WATER; DERIVATIZATION;
D O I
10.1002/jssc.201000541
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the experiment, a high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry with selected reaction monitoring was used to simultaneously determine various classes of phytohormones, including indole-3-acetic acid, a-naphthaleneacetic acid, 2-chlorobenzoic acid, 4-chlorobenzoic acid, indole-3-butyric acid, gibberellic acid, 2,4-dichlorophenoxyacetic acid, 2-naphthoxyacetic acid, abscisic acid, 2,3,5-triiodobenzoic acid, uniconazole, paclobutrazol and 2,4-epibassinolide in rape tissues. The analyses were separated by an HPLC equipped with a reversed-phase column using a binary solvent system composed of methanol and water, both containing 0.1% of formic acid. The matrix effect was also considered and determined. The technology was applied to analyze rape tissues, including roots, stems, leaves, flowers, immature pods and rape seeds. The rape tissues were subjected to ultrasound-assisted extraction and purified by dispersive solid-phase extraction, and then transferred into the liquid chromatography system. The detection limit for each plant hormone was defined by the ratio of signal/background noise (S/N) of 3. The results showed perfect linearity (R(2) values of 0.9987-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, < 1%) and peak areas (RSDs, < 7%) for all target compounds.
引用
收藏
页码:640 / 650
页数:11
相关论文
共 33 条
[31]   On-line concentration and pressurized capillary electrochromatographic analysis of phytolhormones in corn [J].
Wang, Shujuan ;
Jia, Li ;
Xing, Da ;
Chen, Deping ;
Zhao, Jingshan .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (05) :859-864
[32]   Simultaneous determination of several phytohormones in natural coconut juice by hollow fiber-based liquid-liquid-liquid microextraction-high performance liquid chromatography [J].
Wu, Yunli ;
Hu, Bin .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (45) :7657-7663
[33]   Alternative calibration approaches to compensate the effect of co-extracted matrix components in liquid chromatography-electrospray ionisation tandem mass spectrometry analysis of pesticide residues in plant materials [J].
Zrostlíková, J ;
Hajslová, J ;
Poustka, J ;
Begany, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) :13-26