In vivo visualization of abdominal malignancies with acoustic radiation force elastography

被引:172
作者
Fahey, B. J. [1 ]
Nelson, R. C. [2 ]
Bradway, D. P. [1 ]
Hsu, S. J. [1 ]
Dumont, D. M. [1 ]
Trahey, G. E. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Radiol, Durham, NC 27706 USA
关键词
D O I
10.1088/0031-9155/53/1/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The utility of acoustic radiation force impulse (ARFI) imaging for real-time visualization of abdominal malignancies was investigated. Nine patients presenting with suspicious masses in the liver (n = 7) or kidney (n = 2) underwent combined sonography/ARFI imaging. Images were acquired of a total of 12 tumors in the nine patients. In all cases, boundary definition in ARFI images was improved or equivalent to boundary definition in B-mode images. Displacement contrast in ARFI images was superior to echo contrast in B-mode images for each tumor. The mean contrast for suspected hepatocellular carcinomas (HCCs) in B-mode images was 2.9 dB (range: 1.5-4.2) versus 7.5 dB (range: 3.1-11.9) in ARFI images, with all HCCs appearing more compliant than regional cirrhotic liver parenchyma. The mean contrast for metastases in B-mode images was 3.1 dB (range: 1.2-5.2) versus 9.3 dB (range: 5.7-13.9) in ARFI images, with all masses appearing less compliant than regional non-cirrhotic liver parenchyma. ARFI image contrast (10.4 dB) was superior to B-mode contrast (0.9 dB) for a renal mass. To our knowledge, we present the first in vivo images of abdominal malignancies in humans acquired with the ARFI method or any other technique of imaging tissue elasticity.
引用
收藏
页码:279 / 293
页数:15
相关论文
共 65 条
[1]   Value of CT volume imaging for optimal placement of radiofrequency ablation probes in liver lesions [J].
Antoch, G ;
Kuehl, H ;
Vogt, FM ;
Debatin, JF ;
Stattaus, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (11) :1155-1161
[2]   In vivo breast tumor detection using transient elastography [J].
Bercoff, J ;
Chaffai, S ;
Tanter, M ;
Sandrin, L ;
Catheline, S ;
Fink, M ;
Gennisson, JL ;
Meunier, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (10) :1387-1396
[3]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[4]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[5]   Intra-operative Ultrasound Elastography and Registered Magnetic Resonance Imaging of Brain Tumours: A Feasibility Study [J].
Chakraborty, Aabir ;
Berry, Gearoid ;
Bamber, Jeff ;
Dorward, Neil .
ULTRASOUND, 2006, 14 (01) :43-49
[6]   CT AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY - CURRENT TECHNIQUES AND NEW INNOVATIONS [J].
CHARBONEAU, JW ;
READING, CC ;
WELCH, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :1-10
[7]   Assessment of therapeutic response in hepatocellular carcinoma treated with percutaneous radio frequency ablation - Comparison of multiphase helical computed tomography and power Doppler ultrasonography with a microbubble contrast agent [J].
Choi, DG ;
Lim, HK ;
Kim, SH ;
Lee, WJ ;
Jang, HJ ;
Kim, H ;
Lee, SJ ;
Lim, JH .
JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (04) :391-401
[8]   Elastography in the detection of prostatic cancer [J].
Cochlin, DL ;
Ganatra, RH ;
Griffiths, DFR .
CLINICAL RADIOLOGY, 2002, 57 (11) :1014-1020
[9]   Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance [J].
Daly, B ;
Krebs, TL ;
Wong-You-Cheong, JJ ;
Wang, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) :637-644
[10]   Radiofrequency ablation of 100 hepatic metastases with a mean follow-up of more than 1 year [J].
de Baere, T ;
Elias, D ;
Dromain, C ;
El Din, MG ;
Kuoch, V ;
Ducreux, M ;
Boige, V ;
Lassau, N ;
Marteau, V ;
Lasser, P ;
Roche, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (06) :1619-1625