Atomic spectrometry update - X-ray fluorescence spectrometry

被引:15
作者
Ellis, AT
Holmes, M
Kregsamer, P
Potts, PJ
Streli, C
West, M
Wobrauschek, P
机构
[1] Open Univ, Dept Earth Sci, Milton Keynes MK7 6AA, Bucks, England
[2] Oxford Instruments, Ind Anal Grp, Abingdon OX14 1UJ, Oxon, England
[3] Ceram Res, Stoke On Trent ST4 7LQ, Staffs, England
[4] Univ Vienna, Atominst, A-1020 Vienna, Austria
[5] Sheffield Hallam Univ, Mat Res Inst, Sheffield S1 1WB, S Yorkshire, England
关键词
D O I
10.1039/a808049f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The current work continues the annual series of reviews of progress in X-ray fluorescence spectrometry and covers work published during 1997-98, The papers referred to in this review are the ones that in the judgement of the authors made a significant contribution to the advancement of XRF, The style and scope ape very similar to earlier reviews in the series (for example, ref, 1), with a comprehensive coverage of all aspects of XRF, There continue to be important developments in the field, notable amongst which are the very high resolution energy dispersive detector devices, specifically microcalorimeter and superconducting tunnel junction devices. indeed, there is continuing interest in developments in a wide range off solid state detector devices, although mercury(n) iodide is the only detector material yet to challenge Si(Li) or HPGe in some applications. Interest in matrix correction procedures continues to be buoyant, although this year has seen a temporary hiatus in fundamental parameter publications. Laboratory microfluorescence has become well established, not the least because of the availability of commercial instrumentation, some of which incorporates glass capillary optics. Investment in synchrotron radiation facilities continues to be strong, ensuring a continuing stream of research publications, One of the significant trends over the last year has been the large number of TXRF contributions, which cover a large proportion of the traditional XRF areas of application. Equally, there continues to be strong interest in portable XRF, particularly in environmental applications-an area that sorely still has not reached its zenith. In the field of general applications of the technique, there continues to be strong interest in developments in the environmental, industrial;clinical and biological areas. This was another vigorous year in the development of XRF, some of the more important features of which are highlighted in this review.
引用
收藏
页码:209R / 232R
页数:24
相关论文
共 414 条
[1]  
Abbott PH, 1997, X-RAY SPECTROM, V26, P125, DOI 10.1002/(SICI)1097-4539(199705)26:3<125::AID-XRS222>3.0.CO
[2]  
2-G
[3]   Microscopic X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources - Plenary lecture [J].
Adams, F ;
Janssens, K ;
Snigirev, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :319-331
[4]  
ADAMS F, 1997, 30 C SPECTR INT CSI
[5]   Variable selection and multivariate calibration journal of models for X-ray fluorescence spectrometry [J].
Adams, MJ ;
Allen, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (02) :119-124
[6]  
ADAMS MJ, 1997, 30 C SPECTR INT CSI
[7]  
[Anonymous], AIP C P
[8]  
AO Q, 1996, IEEE T NUCL SCI, V2, P823
[9]  
ARAUJO MF, 1998, PITTCON 98 NEW ORL L
[10]   Evaluation of portable X-ray fluorescence instrumentation for in situ measurements of lead on contaminated land [J].
Argyraki, A ;
Ramsey, MH ;
Potts, PJ .
ANALYST, 1997, 122 (08) :743-749