Use of spin echo T2 BOLD in assessment of cerebral misery perfusion at 1.5 T

被引:25
作者
Kavec, M
Gröhn, OHJ
Kettunen, MI
Silvennoinen, MJ
Penttonen, M
Kauppinen, RA
机构
[1] Univ Kuopio, AI Virtanen Inst, Natl Bio NMR Facil, FIN-70211 Kuopio, Finland
[2] Univ Kuopio, AI Virtanen Inst, Cognit Neurobiol Lab, FIN-70211 Kuopio, Finland
关键词
brain; misery perfusion; ischaemia; BOLD; spin echo; oxygen extraction; rat;
D O I
10.1007/BF02678271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Inadequate blood supply relative to metabolic demand, a haemodynamic condition termed as misery perfusion, often occurs in conjunction with acute ischaemic stroke. Misery perfusion results in adaptive changes in cerebral physiology including increased cerebral blood volume (CBV) and oxygen extraction ratio (OER) to secure substrate supply for the brain. It has been suggested that the presence of misery perfusion may be an indication of reversible ischaemia, thus detection of this condition may have clinical impact in acute stroke imaging. The ability of single spin echo T-2 to detect misery perfusion in the rat brain at 1.5 T owing to its sensitivity to blood oxygenation level dependent (BOLD) contrast was studied both theoretically and experimentally. Based on the known physiology of misery perfusion, tissue morphometry and blood relaxation data. T, behaviour in misery perfusion was simulated. The interpretation of these computations was experimentally assessed by quantifying T, in a rat model for cerebral misery perfusion. CBF was quantified with the H-2 clearance method. A drop of CBF from 58 +/- 8 to 17 +/- 3 ml/100 g/min in the parieto-frontal cortex caused shortening of T-2 from 66.9 +/- 0.4 to 64.6 +/- 0.5 ms. Under these conditions, no change in diffusion MRI was detected. In contrast, the cortex with CBF of 42 +/- 7 ml/ 100 g/min showed no change in T-2. Computer simulations accurately predicted these T-2 responses. The present study shows that the acute drop of CBF by 70% causes a negative BOLD that is readily detectable by T-2 MRI at 1.5 T. Thus BOLD may serve as an index of misery perfusion thus revealing viable tissue with increased OER. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 57 条
[1]   SPIN-ECHO NMR STUDIES OF CHEMICAL EXCHANGE .1. SOME GENERAL ASPECTS [J].
ALLERHAND, A ;
GUTOWSKY, HS .
JOURNAL OF CHEMICAL PHYSICS, 1964, 41 (07) :2115-&
[2]   Magnetic resonance imaging of acute stroke [J].
Baird, AE ;
Warach, S .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (06) :583-609
[3]  
Baker, 1979, LAB RAT
[4]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[5]   REVERSAL OF FOCAL MISERY-PERFUSION SYNDROME BY EXTRA-INTRACRANIAL ARTERIAL BYPASS IN HEMODYNAMIC CEREBRAL-ISCHEMIA - A CASE-STUDY WITH O-15 POSITRON EMISSION TOMOGRAPHY [J].
BARON, JC ;
BOUSSER, MG ;
REY, A ;
GUILLARD, A ;
COMAR, D ;
CASTAIGNE, P .
STROKE, 1981, 12 (04) :454-459
[6]  
BENGA G, 1989, INT REV CYTOL, V114, P273
[7]   THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO [J].
BOXERMAN, JL ;
BANDETTINI, PA ;
KWONG, KK ;
BAKER, JR ;
DAVIS, TL ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :4-10
[8]   APPLICATION OF SPIN-ECHO NUCLEAR MAGNETIC-RESONANCE TO WHOLE-CELL SYSTEMS - MEMBRANE-TRANSPORT [J].
BRINDLE, KM ;
BROWN, FF ;
CAMPBELL, ID ;
GRATHWOHL, C ;
KUCHEL, PW .
BIOCHEMICAL JOURNAL, 1979, 180 (01) :37-44
[9]   EXPLANATION OF CEREBRAL WHITE-GRAY CONTRAST IN COMPUTED-TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G ;
KELLER, MR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :489-491
[10]  
Calamante F, 1999, MAGN RESON MED, V41, P479, DOI 10.1002/(SICI)1522-2594(199903)41:3<479::AID-MRM9>3.0.CO