A Non-Contact Pulse Automatic Positioning Measurement System for Traditional Chinese Medicine

被引:25
作者
Chen, Ying-Yun [1 ]
Chang, Rong-Seng [1 ]
Jwo, Ko-Wen [1 ]
Hsu, Chung-Chi [1 ]
Tsao, Chu-Pang [1 ]
机构
[1] Natl Cent Univ, Dept Opt & Photon, Taoyuan 32001, Taiwan
关键词
non-contact; pulse; Traditional Chinese Medicine (TCM); optical triangulation measurements; CMOS IMAGE SENSOR; TCM; PRESSURE;
D O I
10.3390/s150509899
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
This study is to construct a non-contact pulse automatic positioning measurement system for Traditional Chinese Medicine (TCM) using optical triangulation measurements. The system consists of a linear laser, a CMOS image sensor and image analysis software. The linear laser is projected on the pulse beat location on the wrists; the CMOS image sensor records the process and the software analyzes the images. The program mainly uses the optical centroid and fast Fourier transform (FFT) principles to calculate centroid changes (pulse amplitude changes) from the images taken by the CMOS image sensor. It returns the positions of cun, guan and chi pulses automatically in terms of the amplitudes and the signals are then transformed from the time domain (time-amplitude) into the frequency domain (frequency-amplitude) via FFT to obtain the waveforms and frequencies of the cun, guan and chi pulses. It successfully extracts the data from the TCM pulse reading and can be a medical aid system for TCM. Combining the advantages of optical measurement and computer automation, this system provides a non-contact, easy to operate, fast in detection and low-cost equipment design.
引用
收藏
页码:9899 / 9914
页数:16
相关论文
共 18 条
[1]
[Anonymous], DIAGNOSTICS TRADITIO
[2]
HOLISTIC ALTERNATIVE TO SCIENTIFIC MEDICINE - HISTORY AND ANALYSIS [J].
BERLINER, HS ;
SALMON, JW .
INTERNATIONAL JOURNAL OF HEALTH SERVICES, 1980, 10 (01) :133-147
[3]
A Parkinson's Disease Measurement System Using Laser Lines and a CMOS Image Sensor [J].
Chang, Rong-Seng ;
Chiu, Jen-Hwey ;
Chen, Fang-Pey ;
Chen, Jyh-Cheng ;
Yang, Jen-Lin .
SENSORS, 2011, 11 (02) :1461-1475
[4]
Using an array sensor to determine differences in pulse diagnosis-Three positions and nine indicators [J].
Chu, Yu-Wen ;
Luo, Ching-Hsing ;
Chung, Yu-Feng ;
Hu, Chung-Shing ;
Yeh, Cheng-Chang .
EUROPEAN JOURNAL OF INTEGRATIVE MEDICINE, 2014, 6 (05) :516-523
[5]
Possibility of quantifying TCM finger-reading sensations: II. An example of health standardization [J].
Chung, Yu-Feng ;
Hu, Chung-Shing ;
Luo, Ching-Hsing ;
Yeh, Cheng-Chang ;
Si, Xiao-Chen ;
Feng, Da-Hsuan ;
Yeh, Shu-Ming ;
Liang, Chi-Hsien .
EUROPEAN JOURNAL OF INTEGRATIVE MEDICINE, 2012, 4 (03) :E263-E270
[6]
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses [J].
Davies, JI ;
Struthers, AD .
JOURNAL OF HYPERTENSION, 2003, 21 (03) :463-472
[7]
Stroke therapy in traditional Chinese medicine (TCM): prospects for drug discovery and development [J].
Gong, XD ;
Sucher, NJ .
TRENDS IN PHARMACOLOGICAL SCIENCES, 1999, 20 (05) :191-196
[8]
Regression analysis of radial artery pulse palpation as a potential tool for traditional Chinese medicine training education [J].
Huang, Po-Yu ;
Lin, Wen-Chen ;
Chiu, Bill Yuan-Chi ;
Chang, Hen-Hong ;
Lin, Kang-Ping .
COMPLEMENTARY THERAPIES IN MEDICINE, 2013, 21 (06) :649-659
[9]
King Emma, 2002, Acupunct Med, V20, P150
[10]
Cardiorespiratory Fitness, Exercise, and Blood Pressure [J].
Kokkinos, Peter .
HYPERTENSION, 2014, 64 (06) :1160-1164