The neutron fluence and H*(10) response of the new LB 6411 rem counter

被引:94
作者
Burgkhardt, B
Fieg, G
Klett, A
Plewnia, A
Siebert, BRL
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031977
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new rem counter with a response tailored to match the shape of H*(10)/Phi as defined by ICRU and ICRP has been developed recently in the frame of a Technology Transfer Project of the Research Centre Karlsruhe with the industrial partner EG&G Berthold, Wildbad. In this paper, a carefully established, consistent fluence and ambient dose equivalent response function is provided for this detector as well as the effective response calculated for more than 500 neutron spectra from a catalogue.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 8 条
[1]  
[Anonymous], 1990, ICRP PUBL
[2]  
BRIESMEISTER J, 1991, 7396M LA
[3]  
GRIFFITH RV, 1990, TECHN REPORT SERIES, V318
[4]  
GULDBAKKE S, 1994, STRAHLENSCHUTZ PHYSI, V1, P240
[5]  
ICRU, 1993, 51 ICRU
[6]  
KLETT A, 1994, P 4 C RAD PROT DOS O, P227
[7]   A database of neutron spectra, instrument response functions, and dosimetric conversion factors for radiation protection applications [J].
Naismith, OF ;
Siebert, BRL .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :241-245
[8]  
SIEBERT BRL, 1995, RADIAT PROT DOSIM, V58, P177