On the testing of large PV arrays

被引:40
作者
Martinez-Moreno, F. [1 ]
Lorenzo, E. [1 ]
Munoz, J. [1 ]
Moreton, R. [1 ]
机构
[1] Univ Politecn Madrid, ETSI Telecomunicac, Inst Energia Solar, E-28040 Madrid, Spain
来源
PROGRESS IN PHOTOVOLTAICS | 2012年 / 20卷 / 01期
关键词
PV array characterization; PV power; field test; I-V curve; wattmeter;
D O I
10.1002/pip.1102
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reports on the IES-UPM experience from 2006 to 2010 in the field of the characterization of PV arrays of commercial large PV plants installed in Spain within the framework of the profitable economic scenarios associated to feed-in tariff laws. This experience has extended to 200?MW and has provided valuable lessons to minimize uncertainty, which plays a key role in quality assurance procedures. The paper deals not only with classic IV measurements but also with watt-metering-based procedures. Particular attention is paid to the selection of irradiance and cell temperature sensors. Copyright (c) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 32 条
[1]  
Alonso Abella M, 2008, P 23 EUR PHOT SOL EN, P2837
[2]  
Alonso M, 2008, P 14 C IB 9 C IB EN, V2, P991
[3]  
[Anonymous], 1995, 61829 IEC
[4]  
[Anonymous], 2010, INF EST VENT EN REG
[5]  
[Anonymous], 2004, SAND20043535
[6]  
Auer R, 2007, 22 EUR PHOT SOL EN C, P2519
[7]  
Blaesser G, 1995, 16340 EUR EN JOINT R
[8]  
Dupont R, 2009, REV FOTOVOLTAICA NOV, P42
[9]  
Fabero F, 2005, 20 EUR PHOT SOL EN C, P2059
[10]  
Haeberlin H., 2006, P 21 EUR PHOT SOL EN, P2153