Experimental study of natural roof ventilation in full-scale enclosure fire tests in a small compartment

被引:34
作者
Merci, Bart [1 ]
Vandevelde, Paul
机构
[1] Univ Ghent, Dept Flow Heat & Combust Mech, Ghent, Belgium
[2] WFRGENT NV, Ghent, Belgium
关键词
full-scale experiments; natural ventilation; small compartment fire;
D O I
10.1016/j.firesaf.2007.02.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An analysis of full-scale fire test experimental data is presented for a small compartment (3 x 3.6 x 2.3 m). A square steady fire source is placed in the center of the compartment. There is an open door and a horizontal opening in the roof, so that natural ventilation is established for the well-ventilated fire. A parameter study is performed, covering a range of total fire heat release rates (330, 440 and 550 kW), fire source areas (0.3 x 0.3 m and 0.6 x 0.6 m) and roof ventilation opening areas (1.45 x 1 m, 0.75 x 1 m and 0.5 x 1 m). The impact of the different parameters is examined on the smoke layer depth and the temperature variations in vertical direction in the compartment. Both mean temperatures and temperature fluctuations are reported. The total fire heat release rate value has the strongest influence on the hot smoke layer average temperature rise, while the influence of the fire source area and the roof opening is smaller. The hot smoke layer depth, determined from the measured temperature profiles, is primarily influenced by the fire source area, while the total fire heat release rate and the roof opening only have a small impact. Correlations are given for the hot smoke layer average temperature rise, the buoyancy reference velocity and the total smoke mass flow rate out of the compartment, as a function of the different parameters mentioned. Based on the experimental findings, it is discussed that different manual calculation methods, widely used for natural ventilation design of compartments in the case of fire, under-predict the hot layer thickness and total smoke mass flow rate, while the hot layer average temperature is over-estimated. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:523 / 535
页数:13
相关论文
共 14 条
[1]  
[Anonymous], 1999, DESIGN METHODOLOGIES
[2]  
[Anonymous], 2002, SFPE HDB FIRE PROTEC
[3]   A two-thermocouples probe for radiation corrections of measured temperatures in compartment fires [J].
Brohez, S ;
Delvosalle, C ;
Marlair, G .
FIRE SAFETY JOURNAL, 2004, 39 (05) :399-411
[4]  
*CEN, 2000, CR121015 CEN
[5]  
*CIBSE, 1997, CIBSE GUID E FIR ENG
[6]   Tenability conditions and filling times for fires in large spaces [J].
Delichatsios, M .
FIRE SAFETY JOURNAL, 2004, 39 (08) :643-662
[7]  
DRYSDALE D, 2003, INTRO FIRE DYNAMICS
[8]   Nondimensional methods for natural ventilation design [J].
Etheridge, DW .
BUILDING AND ENVIRONMENT, 2002, 37 (11) :1057-1072
[9]   THERMOCOUPLES AND SAMPLE PROBES FOR COMBUSTION STUDIES [J].
HEITOR, MV ;
MOREIRA, ALN .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 1993, 19 (03) :259-278
[10]  
*ISO FDIS, 2004, 92SC4WG9 ISO FDIS