Contact sensitivity to standard series allergens in 1038 patients with contact dermatitis in Turkey

被引:76
作者
Akyol, A [1 ]
Boyvat, A [1 ]
Peksari, Y [1 ]
Gürgey, E [1 ]
机构
[1] Ankara Univ, Tip Fak, Sch Med, Dept Dermatol, TR-06100 Ankara, Turkey
关键词
contact sensitivity; European standard series; patch test; Turkey;
D O I
10.1111/j.0105-1873.2005.00608.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
We planned to determine the frequency of sensitivity to European standard patch test allergens in 1038 patients with contact dermatitis. From 1992 to 2004, 1038 patients with the diagnosis of contact dermatitis were patch tested with the European standard series. Seven hundred and five patients were female (67.9%) and 333 patients were male (32.1%). A total of 336 patients (32.3%) had one or more positive patch test reactions. The most common allergens were nickel (17.6%), cobalt chloride (5.3%), potassium dichromate (4.6%), neomycin (2.4%), fragrance mix (2.1%) and balsam of Peru (2.1%). Contact sensitivity to potassium dichromate and thiuram was significantly more frequent in male patients, whereas nickel and primin sensitivity was significantly more frequent in female patients. Higher sensitivity rates for potassium dichromate, neomycin, balsam of Peru, wool alcohol, fragrance mix and primin were noted in patients over 40 years of age. Sensitivity rates of the standard series allergens were all similar in atopic patients and in non-atopic patients. Metals, neomycin and fragrances are the leading allergens in Turkey. Although fragrances are among the most important sensitizers, sensitivity rates to fragrances and also to preservatives are much lower than the rates in Europe and the US.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 32 条
[1]   Patch test results in 542 patients with suspected contact dermatitis in Turkey [J].
Akasya-Hillenbrand, E ;
Özkaya-Bayazit, E .
CONTACT DERMATITIS, 2002, 46 (01) :17-23
[2]  
Albert M R, 1999, Am J Contact Dermat, V10, P219, DOI 10.1016/S1046-199X(99)90072-6
[3]  
Albert M R, 1998, Am J Contact Dermat, V9, P207, DOI 10.1016/S1046-199X(98)90030-6
[4]   Sensitizations to allergens of the European standard series at the department of dermatology in Zurich 1990-1994 [J].
Bangha, E ;
Elsner, P .
DERMATOLOGY, 1996, 193 (01) :17-21
[5]   Allergic reactions to workplace allergens [J].
Bernstein, DI .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 278 (22) :1907-1913
[6]   The British standard series of contact dermatitis allergens: validation in clinical practice and value for clinical governance [J].
Britton, JER ;
Wilkinson, SM ;
English, JSC ;
Gawkrodger, DJ ;
Ormerod, AD ;
Sansom, JE ;
Shaw, S ;
Statham, B .
BRITISH JOURNAL OF DERMATOLOGY, 2003, 148 (02) :259-264
[7]   The frequency of fragrance allergy in patch-tested patients increases with their age [J].
Buckley, DA ;
Rycroft, RJG ;
White, IR ;
McFadden, JP .
BRITISH JOURNAL OF DERMATOLOGY, 2003, 149 (05) :986-989
[8]   NICKEL DERMATITIS - AN UPDATE [J].
CHRISTENSEN, OB .
DERMATOLOGIC CLINICS, 1990, 8 (01) :37-40
[9]   OCCUPATIONAL ALLERGIC CONTACT-DERMATITIS IN CONSTRUCTION WORKERS [J].
CONDESALAZAR, L ;
GUIMARAENS, D ;
VILLEGAS, C ;
ROMERO, A ;
GONZALEZ, MA .
CONTACT DERMATITIS, 1995, 33 (04) :226-230
[10]  
CRONIN E, 1970, ACTA DERM-VENEREOL, V50, P183