Attenuation-corrected 99mTc-tetrofosmin single-photon emission computed tomography in the detection of viable myocardium:: Comparison with positron emission tomography using 18F-fluorodeoxyglucose

被引:53
作者
Matsunari, I
Böning, G
Ziegler, SI
Nekolla, SG
Stollfuss, JC
Kosa, I
Ficaro, EP
Schwaiger, M
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-81675 Munich, Germany
[2] Univ Michigan, Dept Internal Med, Div Nucl Med, Med Ctr, Ann Arbor, MI 48109 USA
关键词
D O I
10.1016/S0735-1097(98)00340-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to assess the efficacy of attenuation-corrected (AC) technetium-99m (Tc-99m)-tetrofosmin single-photon emission computed tomography (SPECT) in detecting viable myocardium compared to F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET). Background. The role of Tc-99m-labeled perfusion tracers in the assessment of myocardial viability remains controversial. Attenuation artifacts affect the diagnostic accuracy of SPECT images. Methods. Twenty four patients with coronary artery disease (mean left ventricular ejection fraction 30%) underwent resting Tc-99m-tetrofosmin SPECT and FDG PET imaging, Both AC and non-attenuation-corrected (NC) SPECT images were generated, Results. Using a 50% threshold for viability by FDG PET, the percentage of concordant segments of viability between Tc-99m-tetrofosmin and FDG on the patient basis increased from 79.8% +/- 14.0% (mean +/- SD) on the NC images to 90.8% +/- 10.6% on the AC images (p = 0.002). The percentage of Tc-99m-tetrofosmin defect segments within PET-viable segments, an estimate for the degree of underestimation of viability, decreased from 19.8% +/- 15.2% on the NC images to 9.7% +/- 12.6% on the AC images (p = 0.01), Similar results were obtained when a 60% threshold was used to define viability by FDG PET. When the anterior-lateral and inferior septal regions were separately analyzed, the effect of attenuation correction was significant only in the inferior-septal region. Conclusions. The results indicate that AC Tc-99m-tetrofosmin SPECT improves the detection of viable myocardium mainly by decreasing the underestimation of viability particularly in the inferior septal region, although some underestimation/overestimation of viability may still occur even with attenuation correction. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:927 / 935
页数:9
相关论文
共 42 条
[1]  
ALTEHOEFER C, 1994, J NUCL MED, V35, P569
[2]   ATTENUATION CORRECTION IN CARDIAC POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
BACHARACH, SL ;
BUVAT, I .
JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) :246-255
[3]   Predictive value of low dose dobutamine transesophageal echocardiography and fluorine-18 fluorodeoxyglucose positron emission tomography for recovery of regional left ventricular function after successful revascularization [J].
Baer, FM ;
Voth, E ;
Deutsch, HJ ;
Schneider, CA ;
Horst, M ;
deVivie, ER ;
Schicha, H ;
Erdmann, E ;
Sechtem, U .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (01) :60-69
[4]   IDENTIFICATION OF VIABLE MYOCARDIUM IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR DYSFUNCTION - COMPARISON OF THALLIUM SCINTIGRAPHY WITH REINJECTION AND PET IMAGING WITH F-18 FLUORODEOXYGLUCOSE [J].
BONOW, RO ;
DILSIZIAN, V ;
CUOCOLO, A ;
BACHARACH, SL .
CIRCULATION, 1991, 83 (01) :26-37
[5]   Comparison of dobutamine echocardiography and positron emission tomography in patients with chronic ischemic left ventricular dysfunction [J].
Chan, RKM ;
Lee, KJ ;
Calafiore, P ;
Berlangieri, SU ;
McKay, WJ ;
Tonkin, AM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) :1601-1607
[6]   Recovery of regional left ventricular dysfunction after coronary revascularization - Impact of myocardial viability assessed by nuclear imaging and vessel patency at follow-up angiography [J].
Dahl, JV ;
Altehoefer, C ;
Sheehan, FH ;
Buechin, P ;
Uebis, R ;
Messmer, BJ ;
Buell, U ;
Hanrath, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) :948-958
[7]   ENHANCED DETECTION OF ISCHEMIC BUT VIABLE MYOCARDIUM BY THE REINJECTION OF THALLIUM AFTER STRESS REDISTRIBUTION IMAGING [J].
DILSIZIAN, V ;
ROCCO, TP ;
FREEDMAN, NMT ;
LEON, MB ;
BONOW, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (03) :141-146
[8]   MYOCARDIAL VIABILITY IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE - COMPARISON OF TC-99M-SESTAMIBI WITH THALLIUM REINJECTION AND [F-18] FLUORODEOXYGLUCOSE [J].
DILSIZIAN, V ;
ARRIGHI, JA ;
DIODATI, JG ;
QUYYUMI, AA ;
ALAVI, K ;
BACHARACH, SL ;
MARINNETO, JA ;
KATSIYIANNIS, PT ;
BONOW, RO .
CIRCULATION, 1994, 89 (02) :578-587
[9]  
DILSIZIAN V, 1993, CIRCULATION, V87, P1
[10]  
DUVERNOY CS, 1995, J NUCL CARDIOL, V2, P499, DOI 10.1016/S1071-3581(05)80042-X