Canal shapes produced sequentially during instrumentation with Quantec SC rotary nickel-titanium instruments: a study in simulated canals

被引:9
作者
Griffiths, IT
Chassot, AL
Nascimento, MF
Bryant, ST
Dummer, PMH
机构
[1] Univ Wales Coll Cardiff, Coll Med, Sch Dent, Dept Adult Dent Hlth, Cardiff CF14 4XY, S Glam, Wales
[2] Univ Fed Rio Grande do Sul, Sch Dent, Porto Alegre, RS, Brazil
关键词
aberrations; canal shape; nickel-titanium; rotary instruments; simulated canals;
D O I
10.1046/j.1365-2591.2001.00355.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study was to determine the shaping ability of Quantec SC nickel-titanium rotary instruments in simulated root canals. Methodology Forty simulated canals consisting of four different shapes in terms of angle and position of curvature were prepared with Quantec SC instruments. Sequential still images were taken of the canals using a video camera attached to a computer with image analysis software. Images were taken preoperatively, and then after instrument 7 (Size 25, 0.05 taper), instrument 8 (size 25, 0.06 taper), and instrument 10 (size 45, 0.02 taper) were taken to length. Each sequential postoperative image was superimposed individually over the preoperative image in order to highlight the amount and position of material removed during preparation. Results Overall, the mean preparation time to size 10 was 3.6 min with 12 mm canals taking on average less time than 8 mm canals, There was a highly significant difference between the canal types (P < 0.0001), No instruments fractured within the canal or deformed, although one instrument separated from the latch grip. All canals remained patent. Following preparation to size 10, 19 canals (48%) retained their length, eight (20%) lost length, and 13 (32%) gained length; the magnitude of the change in length was always 0.5 mm or below. Following preparation to size 7 instruments all canals showed aberrant shapes. Excess removal of material along the outer aspect of the curve between the beginning of the curve and the end-point (outer widening) was found in 26 canals (65%) after instrument 7. At the same stage of preparation six canals (15%) had zips, three (8%) had ledges and five (13%) had perforations. Following preparation to size 10, 27 (68%) canals were perforated. Conclusions Under the conditions of the study, Quantec SC instruments consistently produced aberrations when canals were enlarged to size 7 (size 25, 0.05 taper) or above. Care should be exercised when using these instruments in real teeth.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 16 条
[1]   SHAPING OF SIMULATED ROOT CANALS IN RESIN BLOCKS USING THE STEP-BACK TECHNIQUE WITH K-FILES MANIPULATED IN A SIMPLE IN OUT FILING MOTION [J].
ALODEH, MHA ;
DOLLER, R ;
DUMMER, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1989, 22 (03) :107-117
[2]  
ALOMARI MAO, 1992, INT ENDOD J, V25, P57, DOI 10.1111/j.1365-2591.1992.tb00738.x
[3]   COMPARISON OF 6 FILES TO PREPARE SIMULATED ROOT CANALS .2. [J].
ALOMARI, MAO ;
DUMMER, PMH ;
NEWCOMBE, RG ;
DOLLER, R ;
HARTLES, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (02) :67-81
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[5]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[6]   Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals [J].
Bryant, ST ;
Dummer, PMH ;
Pitoni, C ;
Bourba, M ;
Moghal, S .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (03) :155-164
[7]   A METHOD FOR THE CONSTRUCTION OF SIMULATED ROOT CANALS IN CLEAR RESIN BLOCKS [J].
DUMMER, PMH ;
ALODEH, MHA ;
ALOMARI, MAO .
INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (02) :63-66
[8]   Canal shapes produced sequentially during instrumentation with Quantec LX rotary nickel-titanium instruments: a study in simulated canals [J].
Griffiths, IT ;
Bryant, ST ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (04) :346-354
[9]  
SCHILDER H, 1984, PATHWAYS PULP, P175
[10]  
Thompson SA, 1998, INT ENDOD J, V31, P268