Undulators at HiSOR - a compact racetrack-type ring

被引:18
作者
Hiraya, A [1 ]
Yoshida, K
Yagi, S
Taniguchi, M
Kimura, S
Hama, H
Takayama, T
Amano, D
机构
[1] Hiroshima Synchrotron Radiat Ctr, Higashihiroshima 739, Japan
[2] Hiroshima Univ, Dept Mat Sci, Higashihiroshima 739, Japan
[3] Hiroshima Univ, Hiroshima Synchrotron Radiat Ctr, Higashihiroshima 739, Japan
[4] UVSOR, Inst Mol Sci, Okazaki, Aichi 444, Japan
[5] Sumitomo Heavy Ind Ltd, Lab Quantum Equipment Technol, Tanashi, Tokyo 188, Japan
关键词
compact rings; HiSOR; insertion devices; helical undulators; linear undulators; helical/linear switchable undulators;
D O I
10.1107/S0909049597018220
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact racetrack-type 700 MeV storage ring (HiSOR) has been constructed at Hiroshima Synchrotron Radiation Center (HSRC). As the ring was planned for synchrotron radiation research on science and technology using VUV to X-rays up to 5 keV with limited size and cost, the ring was designed (i) to realize a high magnetic field (2.7 T) using conventional dipole magnets for higher critical energy, and (ii) to include two straight sections for insertion devices. A linear undulator (25-300 eV) and a new-type helical/linear undulator were installed at the two straight sections. The latter undulator consists of upper and lower jaws, as in a planar undulator; each jaw consists of one fixed magnet array at the centre and two magnet arrays on both sides. By longitudinal displacement of the side magnet arrays, the phase between the Vertical and horizontal magnetic fields, and therefore the polarization (right- or left-circular, elliptical, linear) can be selected. The helical/linear undulator gives almost perfect circular polarization at 4-40 eV in the helical configuration without changing the phase of the magnet arrays, as well as linearly polarized light at 3-300 eV in the linear configuration.
引用
收藏
页码:445 / 447
页数:3
相关论文
共 8 条
  • [1] HORI T, 1996, P 4 INT C SYNCHR RAD, P148
  • [2] Design of a helical undulator for UVSOR
    Kimura, S
    Kamada, M
    Hama, H
    Marechal, XM
    Tanaka, T
    Kitamura, H
    [J]. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 : 437 - 440
  • [3] KITAMURA H, 1993, SYNCHROTN RAD CALCUL, P679
  • [4] AN ELLIPTIC WIGGLER FOR SPRING-8
    MARECHAL, XM
    TANAKA, T
    KITAMURA, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) : 1937 - 1939
  • [5] 1ST OBSERVATION OF UNDULATOR RADIATION FROM APPLE-1
    SASAKI, S
    SHIMADA, T
    YANAGIDA, K
    KOBAYASHI, H
    MIYAHARA, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) : 87 - 91
  • [6] TANAKA T, 1998, SRI 97 M
  • [7] The Hiroshima Synchrotron Radiation Center (HSRC)
    Taniguchi, M
    Ghijsen, J
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1176 - 1179
  • [8] Compact synchrotron light source of the HSRC
    Yoshida, K
    Takayama, T
    Hori, T
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 345 - 347