Masquelet technique with external locking plate for recalcitrant distal tibial nonunion

被引:46
作者
Ma, Ching-Hou [1 ]
Chiu, Yen-Chun [1 ]
Tsai, Kun-Ling [2 ]
Tu, Yuan-Kun [1 ]
Yen, Cheng-Yo [1 ]
Wu, Chin-Hsien [1 ]
机构
[1] I Shou Univ, E Da Hosp, Dept Orthopaed Surg, Kaohsiung, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Dept Phys Therapy, Tainan, Taiwan
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷 / 12期
关键词
Distal tibial nonunion; Masquelet technique; External locking plate; Bone reconstruction; COMPRESSION PLATE; FRACTURES; FIXATOR; RECONSTRUCTION; MANAGEMENT; DEFORMITY; NAIL;
D O I
10.1016/j.injury.2017.10.037
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Objective: In the present retrospective study, we aimed to analyze the results of treatment for recalcitrant distal tibial nonunion using Masquelet technique with locking plate as a definitive external fixator. Materials: We included 15 consecutive cases of distal tibial nonunion treated at our hospital between January 2012 and December 2015. The reconstructive procedure comprised debridement of the nonunion site, deformity correction, stabilization with an external locked plate, defect filling with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique). All patients were followed-up for at least one year. Results: Fracture union occurred in all cases after a median of 6.5 months (range, 5-12 months). Mean ankle motion ranged from 12.3 (range, 5-20) degrees of dorsiflexion to 35 (range, 5-55) degrees of plantar flexion. At the final follow-up, the median Iowa ankle score was 83 (range, 68-91). Eight patients had excellent scores, six had good scores, and one had fail score. Conclusion: Although the current study involved only a small number of patients and the intervention comprised two stages, we consider that the used protocol is a simple and valuable alternative for the treatment of recalcitrant distal tibial nonunion. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2847 / 2852
页数:6
相关论文
共 32 条
[1]
A meta-analysis of endovascular versus surgical reconstruction of femoropopliteal arterial disease [J].
Antoniou, George A. ;
Chalmers, Nicholas ;
Georgiadis, George S. ;
Lazarides, Miltos K. ;
Antoniou, Stavros A. ;
Serracino-Inglott, Ferdinand ;
Smyth, J. Vincent ;
Murray, David .
JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) :242-253
[2]
Functional recovery in patients with nonunion treated with the Ilizarov technique [J].
Barker, KL ;
Lamb, SE ;
Simpson, AHRW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :81-85
[3]
Carroll Eben A, 2011, J Surg Orthop Adv, V20, P74
[4]
PREVENTION OF INFECTION IN TREATMENT OF 1000 AND 25 OPEN FRACTURES OF LONG BONES - RETROSPECTIVE AND PROSPECTIVE ANALYSES [J].
GUSTILO, RB ;
ANDERSON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) :453-458
[5]
Locked plating in orthopaedic trauma: A clinical update [J].
Haidukewych, George . ;
Ricci, William .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (06) :347-355
[6]
INDIRECT REDUCTION AND TENSION-BAND PLATING OF TIBIAL NONUNION WITH DEFORMITY [J].
HELFET, DL ;
JUPITER, JB ;
GASSER, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1286-1297
[7]
Janssen KW, 2007, INT ORTHOP, V31, P709, DOI 10.1007/s00264-006-0237-1
[8]
The management of fractures with bone loss [J].
Keating, JF ;
Simpson, AHRW ;
Robinson, CM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :142-150
[9]
Supercutaneous Plating: Use of a Locking Compression Plate as an External Fixator [J].
Kloen, Peter .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (01) :72-75
[10]
Krappinger D, 2015, OPER ORTHOP TRAUMATO, V27, P357, DOI 10.1007/s00064-014-0300-9