Methods of tophus assessment in clinical trials of chronic gout: a systematic literature review and pictorial reference guide

被引:61
作者
Dalbeth, Nicola [1 ]
Schauer, Cameron
MacDonald, Patricia [2 ]
Perez-Ruiz, Fernando [3 ,4 ]
Schumacher, H. Ralph [5 ,6 ]
Hamburger, Steve [7 ]
Choi, Hyon K. [8 ]
McQueen, Fiona M.
Doyle, Anthony
Taylor, William J. [9 ]
机构
[1] Univ Auckland, Dept Med, Fac Med & Hlth Sci, Auckland, New Zealand
[2] Takeda Global Res & Dev, Deerfield, IL USA
[3] Hosp Cruces, Rheumatol Sect, Baracaldo, Pais Vasco, Spain
[4] Hosp Cruces, Div Nephrol, Baracaldo, Pais Vasco, Spain
[5] Univ Penn, Philadelphia, PA 19104 USA
[6] VA Med Ctr, Philadelphia, PA USA
[7] Savient Pharmaceut Inc, E Brunswick, NJ USA
[8] Boston Univ, Sch Med, Boston, MA 02118 USA
[9] Univ Otago, Wellington, New Zealand
关键词
TOPHACEOUS GOUT; COMPUTED-TOMOGRAPHY; QUANTITATIVE-ANALYSIS; PHYSICAL MEASUREMENT; ALLOPURINOL; FEBUXOSTAT; URATE; HYPERURICEMIA; DIAGNOSIS; JOINT;
D O I
10.1136/ard.2010.139899
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To identify methods of tophus measurement for gout studies, summarise the properties of these methods and compile a detailed pictorial reference guide to demonstrate the methods. Methods A systematic search strategy for methods of tophus measurement was formulated. For each method, papers were assessed by two reviewers to summarise information according to the specific components of the Outcomes Measures in Rheumatology (OMERACT) filter: feasibility, truth and discrimination. Detailed images were obtained to construct the reference guide. Results Eight methods of tophus measurement were identified: counting the total number of tophi, physical measurement using tape measure, physical measurement using Vernier callipers, digital photography, ultrasonography (US), MRI, CT and dual energy CT. Feasibility aspects of the methods are well documented. Physical measurement techniques are more feasible than advanced imaging methods, but do not allow for assessment of intra-articular tophi or for data storage and central reading. The truth aspect of the filter has been documented for many methods, particularly Vernier callipers, US, MRI and CT. Reliability of most methods has been reported as very good or excellent. Sensitivity to change has been reported for all methods except MRI and CT. Conclusion A variety of methods of tophus assessment have been described for use in clinical trials of chronic gout. Physical measurement techniques (particularly the Vernier calliper method) and US measurement of tophus size appear to meet most aspects of the OMERACT filter.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 29 条
[1]  
Abufayyah M, 2010, AM COLL RHEUM ANN SC
[2]   Dual Energy CT - a New Perspective in the Diagnosis of Gout [J].
Artmann, A. ;
Ratzenboeck, M. ;
Noszian, I. ;
Trieb, K. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (03) :261-266
[3]   Febuxostat compared with allopurinol in patients with hyperuricemia and gout [J].
Becker, MA ;
Schumacher, HR ;
Wortmann, RL ;
MacDonald, PA ;
Eustace, D ;
Palo, WA ;
Streit, J ;
Joseph-Ridge, N .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (23) :2450-2461
[4]   Clinical Efficacy and Safety of Successful Longterm Urate Lowering with Febuxostat or Allopurinol in Subjects with Gout [J].
Becker, Michael A. ;
Schumacher, H. Ralph ;
MacDonald, Patricia A. ;
Lloyd, Eric ;
Lademacher, Christopher .
JOURNAL OF RHEUMATOLOGY, 2009, 36 (06) :1273-1282
[5]  
Boers M, 1998, J RHEUMATOL, V25, P198
[6]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[7]   Tophaceous joint disease strongly predicts hand function in patients with gout [J].
Dalbeth, N. ;
Collis, J. ;
Gregory, K. ;
Clark, B. ;
Robinson, E. ;
McQueen, F. M. .
RHEUMATOLOGY, 2007, 46 (12) :1804-1807
[8]   Mechanisms of bone erosion in gout: a quantitative analysis using plain radiography and computed tomography [J].
Dalbeth, N. ;
Clark, B. ;
Gregory, K. ;
Gamble, G. ;
Sheehan, T. ;
Doyle, A. ;
McQueen, F. M. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (08) :1290-1295
[9]   Computed tomography measurement of tophus volume: Comparison with physical measurement [J].
Dalbeth, Nicola ;
Clark, Barnaby ;
Gregory, Kate ;
Gamble, Gregory D. ;
Doyle, Anthony ;
McQueen, Fiona M. .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2007, 57 (03) :461-465
[10]   Cellular Characterization of the Gouty Tophus A Quantitative Analysis [J].
Dalbeth, Nicola ;
Pool, Bregina ;
Gamble, Greg D. ;
Smith, Timothy ;
Callon, Karen E. ;
McQueen, Fiona M. ;
Cornish, Jillian .
ARTHRITIS AND RHEUMATISM, 2010, 62 (05) :1549-1556