A primary isotopic gas standard for krypton with values for isotopic composition and molar mass traceable to the Systeme International d'Unites

被引:16
作者
Argebe, Y
Valkiers, S [1 ]
Poths, J
Norgaard, J
Kipphardt, H
De Bièvre, P
Taylor, PDP
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[2] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[3] Bundesanstalt Mat Forsch & Prufung, D-12489 Berlin, Germany
关键词
primary isotopic gas standard; molar mass; isotopic composition; gas isotope mass spectrometry; isotope amount ratio; traceability; SI; krypton;
D O I
10.1016/S1387-3806(00)00397-3
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Isotope amount ratios of krypton were measured on subsamples from one large batch of high purity krypton separated from the atmosphere. Synthetic mixtures of enriched krypton isotopes were used to "calibrate" the measurements with small uncertainties. The result is a primary isotopic gas standard (PIGS) IRMM-2030 with certified values for isotope ratios, isotopic composition, and molar mass of krypton with small combined uncertainties u(c), evaluated according to the ISO/BIPM Guide (GUM). It is commercially available from IRMM-Geel or from MESSER (Duisburg, D). The certified krypton isotope amount ratios in the PIGS IRMM-2030 are as follows: n(Kr-78)/n(Kr-84)=0.006 232 5(55), n(Kr-80)/n(Kr-84)=0.040 107(17), n(Kr-82)/n(Kr-84)=0.203 43(17), n(Kr-83)/n(Kr-84)=0.201 79(11), and n(Kr-86)/n(Kr-84)=0.303 205(59) with expanded uncertainty U=ku(c) and coverage factor k=2, The molar mass of Kr in this sample is M(Kr)=83,798 02(16) g/mol. These values are in good agreement with published measurements of atmospheric krypton but have smaller combined uncertainties and are "calibrated" by means of synthetic isotope mixtures. The values of the PIGS are traceable to the SI. Measurements of isotope amount ratios of krypton in other samples can be linked to SI using this PIGS. (Int J Mass Spectrom 206 (2001) 129-136) (C) 2001 Elsevier Science B.V.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 29 条
  • [1] [Anonymous], 1993, GUID EXPR UNC MEAS G
  • [2] Comparative isotopic measurements on xenon and krypton
    Aregbe, Y
    Valkiers, S
    Mayer, K
    DeBievre, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 153 (01): : L1 - L5
  • [3] AREGBE Y, 1998, THESIS U TECHNOLOGY
  • [4] AREGBE Y, 1994, METROLOGIA, V31, P245
  • [5] THE 1993 ATOMIC MASS EVALUATION .1. ATOMIC MASS TABLE
    AUDI, G
    WAPSTRA, AH
    [J]. NUCLEAR PHYSICS A, 1993, 565 (01) : 1 - 65
  • [6] BASHFORD JR, 1973, GEOCHIM COSMOCHIM S, V4, P1915
  • [7] Atmospheric analysis using a microwave plasma ionization source and ion trap mass spectrometry
    Cisper, ME
    Garrett, AW
    Duan, YXX
    Olivares, JA
    Hemberger, PH
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 178 (1-2) : 121 - 128
  • [8] DEBIEVRE P, 1994, METROLOGIA, V31, P245, DOI 10.1088/0026-1394/31/3/010
  • [9] FLORKOWSKI T, 1986, HDB ENV ISOTOPE GEOC, V2
  • [10] Adsorption in gas mass spectrometry .1. Effects on the measurement of individual isotopic species
    Gonfiantini, R
    Valkiers, S
    Taylor, PDP
    DeBievre, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 163 (03): : 207 - 219