Reversed-phase ion-pair liquid chromatography of a pharmaceutical compound and its photolytically transformed isomer

被引:6
作者
Hsu, LC [1 ]
机构
[1] SmithKline Beecham Pharmaceut, Environm Res Lab, King Of Prussia, PA 19406 USA
关键词
D O I
10.1080/10826079808001252
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reversed-phase HPLC is usually the method of choice for compounds that dissolve in water/organic mixtures, even for samples that contain ionizable compounds. However, reversed-phase ion-pair chromatography (RP-IPC) is often a useful alternative for such samples, particularly if the components are highly basic or acidic. With this technique an aqueous/organic mobile phase is used along with a buffer and an ion-pairing reagent to provide more retention and higher selectivity than are afforded by the column and organic solvents alone. The retention effects of ammonium acetate, sodium acetate, potassium phosphate, and triethylamine (TEA) on a pharmaceutical compound (SK&F 108566) and its stereoisomer (SB 206328) were studied. Evidence indicated that SK&F 108566 and SE 206328 exhibited ion-pair formation with simple buffer systems and the ion-pair occurred in the mobile phase prior to the complex binding rapidly to the stationary phase.
引用
收藏
页码:1685 / 1700
页数:16
相关论文
共 29 条
[2]  
BIDLINGMEYER BA, 1983, LIQ CHROMATOGR HPLC, V1, P345
[3]   Retention of ionizable compounds on HPLC. pH scale in methanol-water and the pK and pH values of buffers [J].
Bosch, E ;
Bou, P ;
Allemann, H ;
Roses, M .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3651-3657
[4]  
BRUM JA, COMMUNICATION
[5]   RETENTION MECHANISMS IN CYANOPROPYL NORMAL BONDED PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
COOPER, WT ;
SMITH, PL .
JOURNAL OF CHROMATOGRAPHY, 1986, 355 (01) :57-74
[6]  
GLAJCH JL, 1983, ANAL CHEM, V55, pA319, DOI 10.1021/ac00253a866
[7]   PRACTICAL ASPECTS OF REVERSE PHASE ION-PAIR CHROMATOGRAPHY [J].
GLOOR, R ;
JOHNSON, EL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (09) :413-423
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .46. SELECTIVITY EFFECTS OF PEPTIDIC POSITIONAL ISOMERS AND OLIGOMERS SEPARATED BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HEARN, MTW ;
GREGO, B .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :75-87
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF AMINO-ACIDS, PEPTIDES AND PROTEINS .40. FURTHER-STUDIES ON THE ROLE OF THE ORGANIC MODIFIER IN THE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF POLYPEPTIDES - IMPLICATIONS FOR GRADIENT OPTIMIZATION [J].
HEARN, MTW ;
GREGO, B .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :125-136
[10]  
HERN MTW, 1980, ADV CHROMATOGR, V18, P59