A year-round dynamic simulation of a solar-driven ejector refrigeration system with iso-butane as a refrigerant

被引:73
作者
Pridasawas, Wimolsiri [1 ]
Lundqvisti, Per [1 ]
机构
[1] Dept Energy Technol, Div Appl Thermodynam & Refrigerat, SE-10044 Stockholm, Sweden
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2007年 / 30卷 / 05期
关键词
air conditioning; ejector system; isobutane; R600a; heating; solar collector; simulation; performance;
D O I
10.1016/j.ijrefrig.2006.11.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the performance of the solar-driven ejector refrigeration system with iso-butane (R600a) as the refrigerant is studied. The effects that both the operating conditions and the solar collector types have on the system's performance are also examined by dynamic simulation. The TRNSYS and EES simulation tools are used to model and analyze the performance of a solar-driven ejector refrigeration system. The whole system is modelled under the TRNSYS environment, but the model of the ejector refrigeration subsystem is developed in the Engineering Equations Solver (EES) program. A solar fraction of 75% is obtained when using the evacuated tube solar collector. In the very hot environment, the system requires relatively high generator temperature, thus a flat plate solar collector is not economically competitive because the high amount of auxiliary heat needed to boost up the generator temperature. The results from the simulation indicate that an efficient ejector system can only work in a region with decent solar radiation and where a sufficiently low condenser temperature can be kept. The average yearly system thermal ratio (STR) is about 0.22, the COP of the cooling subsystem is about 0.48, and the solar collector efficiency is about 0.47 at T-e 15 degrees C, T-c 5 degrees C above the ambient temperature, evacuated collector area 50 m(2) and hot storage tank 3 volume 2 m (c) 2006 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:840 / 850
页数:11
相关论文
共 27 条
[1]   An experimental study of an ejector cycle refrigeration machine operating on R113 [J].
Al-Khalidy, N .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (08) :617-625
[2]  
AlKhalidy N, 1997, INT J ENERG RES, V21, P1123, DOI 10.1002/(SICI)1099-114X(19971010)21:12<1123::AID-ER313>3.0.CO
[3]  
2-B
[4]  
*ASHRAE, 1983, STEAM JET REFR EQ, pCH13
[5]   Experimental study of the performance characteristics of a steam-ejector refrigeration system [J].
Chen, YM ;
Sun, CY .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 15 (04) :384-394
[6]  
Cheng S., 1998, ASIAN J MATH, V2, P153, DOI DOI 10.4310/AJM.1998.V2.N1.A5
[7]   Performance comparison of vapour jet refrigeration system with environment friendly working fluids [J].
Cizungu, K ;
Mani, A ;
Groll, M .
APPLIED THERMAL ENGINEERING, 2001, 21 (05) :585-598
[8]   Mathematical simulation of a solar ejector-compression refrigeration system [J].
Dorantes, R ;
Estrada, CA ;
Pilatowsky, I .
APPLIED THERMAL ENGINEERING, 1996, 16 (8-9) :669-675
[9]   A THEORETICAL AND EXPERIMENTAL-STUDY OF A SMALL-SCALE STEAM JET REFRIGERATOR [J].
EAMES, IW ;
APHORNRATANA, S ;
HAIDER, H .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06) :378-386
[10]   A new prescription for the design of supersonic jet-pumps: the constant rate of momentum change method [J].
Eames, IW .
APPLIED THERMAL ENGINEERING, 2002, 22 (02) :121-131