Breast sentinel lymph node navigation with three-dimensional interstitial multidetector-row computed tomographic lymphography

被引:58
作者
Suga, K
Yamamoto, S
Tangoku, A
Oka, M
Kawakami, Y
Matsunaga, N
机构
[1] Yamaguchi Univ, Sch Med, Dept Radiol, Ube, Yamaguchi 7558505, Japan
[2] Yamaguchi Univ, Sch Med, Dept Surg 2, Ube, Yamaguchi 7558505, Japan
关键词
breast cancer; sentinel lymph node; computed tomography; lymphography; contrast agent;
D O I
10.1097/01.rli.0000164153.41638.32
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Three-dimensional multi detector-row computed tomographic lymphography (3D MDCT-LG) with interstitial injection of a widely available nonionic monometric contrast medium iopamidol was used for navigation of breast sentinel lymph node (SLN) biopsy. Methods: 3D MDCT-LG was obtained after massage of the interstitially injection sites of a total of 4-5 mL undiluted iopamidol at periareolar and peritumoral areas in 68 consecutive patients with early-stage breast cancer, using a 4 detector-row CT scanner. Drainage lymphatic patterns and SLN anatomy were assessed on 3D MDCT-LG images. 3D MDCT-LG-navigated SLN biopsy with combined use of blue dye was followed by backup axillary lymph node dissection to evaluate accuracy of SLN biopsy. Results: The 3D MDCT-LG images clearly localized primary SLNs by visualizing the direct connection between these nodes and their afferent lymphatic vessels on detailed anatomy of the surrounding structures in all patients. Drainage lymphatic pathways on these images were classified into 4 patterns: single route/single SLN (39 cases, 57%), multiple routes/multiple SLNs (10 cases, 15%), single route/multiple SLNs (9 cases, 13%), and multiple routes/single SLN (10 cases, 15%). Under 3D MDCT-LG navigation, SLNs was found at the accurate location in all patients. With backup axillary lymph node dissection, metastasis was found in 14 (20%) patients, and 8 of these patients had metastasis only in the preoperatively identified SLNs. In other 5 positive patients, metastasis was found both in the SLN and non-SLNs. However, micrometastasis eventually was found only in non-SLN in an elderly patient. Overall, the sensitivity, false-negative rate, and accuracy of 3D CT-L-navigated SLN biopsy were 92% (13/14 patients), 7% (1/14 patients), and 98% (67/68 patients), respectively. Conclusions: Topographic 3D interstitial MDCT-LG can be a widely available and reliable navigator for breast SLN biopsy.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 50 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]   Sentinel lymph node biopsy in breast cancer: Guidelines and pitfalls of lymphoscintigraphy and gamma probe detection [J].
Borgstein, P ;
Pijpers, R ;
Comans, EF ;
van Diest, PJ ;
Boom, RP ;
Meijer, S .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (03) :275-283
[3]  
CASLEYSMITH JR, 1983, LYMPHANGIOLOGY, P27
[4]   Guidelines for sentinel node biopsy and lymphatic mapping of patients with breast cancer [J].
Cox, CE ;
Pendas, S ;
Cox, JM ;
Joseph, E ;
Shons, AR ;
Yeatman, T ;
Ku, NN ;
Lyman, GH ;
Berman, C ;
Haddad, F ;
Reintgen, DS .
ANNALS OF SURGERY, 1998, 227 (05) :645-653
[5]   Clinical relevance of parasternal uptake in sentinel node procedure for breast cancer [J].
Fabry, HFJ ;
Mutsaers, PGNJ ;
Meijer, S ;
Torrenga, H ;
Pijpers, R ;
Van Leeuwen, PAM ;
Van der Sijp, JRM .
JOURNAL OF SURGICAL ONCOLOGY, 2004, 87 (01) :13-18
[6]   Incidence of internal mammary node metastases after a sentinel lymph node technique in breast cancer and its implication in the radiotherapy plan [J].
Farrús, B ;
Vidal-Sicart, S ;
Velasco, M ;
Zanón, G ;
Fernández, PL ;
Muñoz, M ;
Santamaría, G ;
Albanell, J ;
Biete, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03) :715-721
[7]   Limitation in gamma probe localization of the sentinel node in breast cancer patients with large excisional biopsy [J].
Feldman, SM ;
Krag, DN ;
McNally, RK ;
Moor, BB ;
Weaver, DL ;
Klein, P .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 188 (03) :248-254
[8]   Interstitial magnetic resonance lymphography with gadobutrol in rats - Evaluation of contrast kinetics [J].
Fink, C ;
Bock, M ;
Kiessling, F ;
Delorme, S .
INVESTIGATIVE RADIOLOGY, 2002, 37 (12) :655-662
[9]  
Fukui Y, 2001, CANCER, V92, P2868, DOI 10.1002/1097-0142(20011201)92:11<2868::AID-CNCR10129>3.0.CO
[10]  
2-I