Simplified voltage-sag filler for line-interactive uninterruptible power supplies

被引:34
作者
Arias Perez de Azpeitia, Manuel [1 ]
Fernandez, Arturo [1 ,2 ]
Gonzalez Lamar, Diego [1 ]
Rodriguez, Miguel [1 ]
Maria Hernando, Marta [1 ]
机构
[1] Univ Oviedo, Dept Elect & Elect Engn, Gijon 33204, Spain
[2] European Space Agcy, Power & Energy Convers Div, F-75738 Paris, France
关键词
filler; notch; sag; simplified; uninterruptible power supply (UPS);
D O I
10.1109/TIE.2008.918595
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
There are three types of static uninterruptible power supplies (UPSs): passive standby, line interactive, and double conversion. The last one protects the load against all types of line disturbances, but it is the most expensive and the one with the lowest efficiency. On the other hand, passive-standby and line-interactive UPSs have higher efficiency and lower cost, but they show an important drawback: a switching time from normal to stored-energy mode. As a consequence, there is a notch in the UPS output voltage during this switching time. In a previous paper, the authors proposed a method for filling these voltage notches with a sinusoidal waveform generated by a switch-mode converter. In this one, a simplified notch filler is proposed. It consists of two capacitors, one charged with positive voltage and the other with negative voltage. If the fault occurs in the positive period, the positive-charged capacitor is connected to the load. This connection is then modulated in order to obtain a sinusoidal waveform at the load. In the negative period, the other capacitor is used in the same way.
引用
收藏
页码:3005 / 3011
页数:7
相关论文
共 22 条
  • [1] BEAUDET JP, 1999, UPS TOPOLOGIES STAND
  • [2] BEKIAROV SB, 2002, P APEC DALL TX MAR 1, V1, P567
  • [3] A three-phase line-interactive UPS system implementation with series-parallel active power-line conditioning capabilities
    da Silva, SAO
    Donoso-Garcia, PF
    Cortizo, PC
    Seixas, PF
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (06) : 1581 - 1590
  • [4] Unified approach for mitigating voltage sag and voltage flicker using the DSTATCOM
    Elnady, A
    Salama, MMA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 992 - 1000
  • [5] FERNANDEZ A, 2006, P APEC MAR 19 23, P341
  • [6] Uninteruptible Power Supply Systems Provide Protection
    Guerrero, Josep M.
    Garcia De Vicuna, Luis
    Uceda, Javier
    [J]. IEEE INDUSTRIAL ELECTRONICS MAGAZINE, 2007, 1 (01) : 28 - 38
  • [7] Three of a kind
    Karve, S
    [J]. IEE REVIEW, 2000, 46 (02): : 27 - 31
  • [8] Kim JHR, 2003, 42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, P3281
  • [9] Improved single-phase line-interactive UPS
    Kwon, BH
    Choi, JH
    Kim, TW
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (04) : 804 - 811
  • [10] Highly scalable non-volatile and ultra-lowpower phase-change nanowire memory
    Lee, Se-Ho
    Jung, Yeonwoong
    Agarwal, Ritesh
    [J]. NATURE NANOTECHNOLOGY, 2007, 2 (10) : 626 - 630