A portable, high-speed, vacuum-outlet GC vapor analyzer employing air as carrier gas and surface acoustic wave detection

被引:52
作者
Whiting, JJ
Lu, CJ
Zellers, ET
Sacks, RD [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Environm Hlth Sci, Ctr Wireless Integrated Microsyst, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac0103726
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vacuum-outlet GC with atmospheric-pressure air as the carrier gas is implemented at outlet pressures up to 0.8 atm using a low-dead-volume polymer-coated surface acoustic wave (SAW) detector. Increases in the system outlet pressure from 0.1 to 0.8 atm lead to proportional increases in detector sensitivity and significant increases in column efficiency. The latter effect arises from the fact that optimal carrier gas velocities are lower in air than in more conventional carrier gases such as helium or hydrogen due to the smaller binary diffusion coefficients of vapors in air. A 12-m-long, 0.25-mm-i.d. tandem column ensemble consisting of 4.5-m dimethyl polysiloxane and 7.5-m trifluoropropylmethyl polysiloxane operated at an outlet pressure of 0.5 atm provides up to 4 x 10(4) theoretical plates and a peak capacity of 65 (resolution, 1.5) for a 3-min isothermal analysis. At 30 degreesC, mixtures of vapors ranging in vapor pressure from 8.6 to 76 Torr are separated in this time frame. The SAW detector cell has an internal volume of <2 muL, which allows the use of higher column outlet pressures with minimal dead time. The sensor response is linear with solute mass over at least 2-3 decades and provides detection limits of 20-50 ng for the vapors tested. The combination of atmospheric-pressure air as carrier gas, modest operating pressures, and SAW sensor detection is well-suited for field instrumentation since it eliminates the need for support gases, permits smaller, low-power pumps to be used, and provides sensitivity to a wide range of vapor analytes.
引用
收藏
页码:4668 / 4675
页数:8
相关论文
共 45 条
[1]   HIGH-SPEED GC AIR MONITOR USING CRYOINTEGRATION FOR SAMPLE COLLECTION [J].
AKARD, M ;
SACKS, RD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (11) :499-505
[2]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[3]   Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors [J].
Cai, QY ;
Park, J ;
Heldsinger, D ;
Hsieh, MD ;
Zellers, ET .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :121-130
[4]   Application of piezoelectric Ru(III)/cryptand-coated quartz crystal gas chromatographic detector for olefins [J].
Chang, P ;
Shih, JS .
ANALYTICA CHIMICA ACTA, 1999, 380 (01) :55-62
[5]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[6]   Novel column heater for fast capillary gas chromatography [J].
Ehrmann, EU ;
Dharmasena, HP ;
Carney, K ;
Overton, EB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (12) :533-539
[7]  
FRYE GC, 1994, EL SOC M MIAM BEACH, P1046
[8]  
Frye-Mason G, 2000, MESA MG, P229
[9]   A NEW METHOD FOR PREDICTION OF BINARY GAS-PHASE DIFFUSION COEFFECIENTS [J].
FULLER, EN ;
SCHETTLE, PD ;
GIDDINGS, JC .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (05) :19-+
[10]  
Golay M.J. E., 1958, GAS CHROMATOGR INT S, P36