A method to obtain surface strains of soft tissues using a laser scanning device

被引:24
作者
Heuer, Frank [1 ]
Wolfram, Uwe [1 ]
Schmidt, Hendrik [1 ]
Wilke, Hans-Joachim [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
关键词
intervertebral disc bulging; lumbar spine; finite element analysis; validation; calibration; image correlation; phase correlation; Fourier; in-plane strain;
D O I
10.1016/j.jbiomech.2008.05.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A three-dimensional laser scanning device was developed allowing Surface digitization of musculoskeletal and soft tissue structures under different loads. linage-processing algorithms were formulated for image registration. These were used to determine displacement mapping and then Surface strains. Various validation experiments were performed. Accuracy was obtained on a test cylinder after rigid rotation and oil a silicon cylinder compressed in four loading steps. The system accuracy (including the scanning and the data evaluation) was +/- 0.10% strain in vertical and +/- 0.16% strain in shear and circumferential direction for the rigid rotation exhibiting the zero-strain situation. Silicon cylinder compression showed that the accuracy was best for small strains, whereas strains > 5% evoked a slight underestimation increasing further with higher strains (error of 0.54% for 7.22% vertical strain). It was possible to increase the accuracy by performing the strain measurements via sub-steps. This had a remaining error of 0.41% (or 7.22% vertical strain. A further experiment was carried out in order to acquire the surface strain of a human lumbar intervertebral disc while it was forced to flexion and extension. This study introduced a laser-based scanning method to obtain soft tissue surface strains. It is important to know the strain distribution of musculoskeletal structures and soft tissues. This could help to better understand the mechanical loading of biological structures e.g. the processes in fracture healing. These data could also be used to assist in the validation process for finite-element models. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2402 / 2410
页数:9
相关论文
共 36 条
[1]
ARGYRIOU V, 2006, 17 BMVC BRIT MACH VI
[2]
Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[3]
BETSCH DF, 1980, BIORHEOLOGY, V17, P83
[4]
A noncontact, nondestructive method for quantifying intratissue deformations and strains [J].
Bey, MJ ;
Song, HK ;
Wehrli, FW ;
Soslowsky, LJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02) :253-258
[5]
Acquisition of full-field strain distributions on ovine fracture callus cross-sections with electronic speckle pattern interferometry [J].
Bottlang, Michael ;
Mohr, Marcus ;
Simon, Ulrich ;
Claes, Lutz .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :701-705
[6]
THE INFLUENCE OF VERTEBRAL BODY FRACTURE, INTRADISCAL INJECTION, AND PARTIAL DISCECTOMY ON THE RADIAL BULGE AND HEIGHT OF HUMAN LUMBAR DISKS [J].
BRINCKMANN, P ;
HORST, M .
SPINE, 1985, 10 (02) :138-145
[7]
SOME MECHANICAL TESTS ON THE LUMBOSACRAL SPINE WITH PARTICULAR REFERENCE TO THE INTERVERTEBRAL DISCS - A PRELIMINARY REPORT [J].
BROWN, T ;
HANSEN, RJ ;
YORRA, AJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1957, 39 (05) :1135-1164
[8]
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[9]
Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing [J].
Claes, LE ;
Heigele, CA .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :255-266
[10]
COSTI JJ, 2006, J BIOMECHAN IN PRESS, DOI DOI 10.1016/I.JBIOMECH.2006.11.006