Circadian variation of paroxysmal atrial fibrillation

被引:25
作者
Gillis, AM
Connolly, SJ
Dubuc, M
Yee, R
Lacomb, P
Philippon, F
Kerr, CR
Kimber, S
Gardner, MJ
Tang, ASL
Molin, F
Newman, D
Abdollah, H
机构
[1] Univ Calgary, Div Cardiol, Calgary, AB T2N 4N1, Canada
[2] McMaster Univ, Div Cardiol, Hamilton, ON, Canada
[3] Univ Montreal, Div Cardiol, Montreal, PQ, Canada
[4] Univ Western Ontario, Div Cardiol, London, ON, Canada
[5] Quebec Heart Inst, Div Cardiol, Quebec City, PQ, Canada
[6] Univ British Columbia, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[7] Univ Alberta, Div Cardiol, Edmonton, AB, Canada
[8] Dalhousie Univ, Div Cardiol, Halifax, NS, Canada
[9] Univ Ottawa, Div Cardiol, Ottawa, ON, Canada
[10] Univ Toronto, Div Cardiol, Toronto, ON, Canada
[11] Queens Univ, Div Cardiol, Kingston, ON, Canada
关键词
D O I
10.1016/S0002-9149(00)01509-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The circadian variation of paroxysmal atrial fibrillation (AF) was studied in 67 patients who received a dual-chamber pacemaker 3 months before a planned atrioventricular node ablation. A distinct circadian variation of AF was observed with 2 time peaks in initiation (1 in the early morning and 1 in the early evening hours), which was modulated by atrial pacing, the duration of AF, and the use of beta -adrenergic blocking agents.
引用
收藏
页码:794 / +
页数:6
相关论文
共 20 条
[1]   DDD PACING - AN EFFECTIVE TREATMENT MODALITY FOR RECURRENT ATRIAL ARRHYTHMIAS [J].
ATTUEL, P ;
PELLERIN, D ;
MUGICA, J ;
COUMEL, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1647-1654
[2]   SPONTANEOUS OCCURRENCE OF SYMPTOMATIC PAROXYSMAL ATRIAL-FIBRILLATION AND PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIA IN UNTREATED PATIENTS [J].
CLAIR, WK ;
WILKINSON, WE ;
MCCARTHY, EA ;
PAGE, RL ;
PRITCHETT, ELC .
CIRCULATION, 1993, 87 (04) :1114-1122
[3]   High rate atrial tachyarrhythmia detections in implantable pulse generators: Low incidence of false-positive detections [J].
Fitts, SM ;
Hill, MRS ;
Mehra, R ;
Gillis, AM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (07) :1080-1086
[4]   Atrial pacing periablation for prevention of paroxysmal atrial fibrillation [J].
Gillis, AM ;
Wyse, DG ;
Connolly, SJ ;
Dubuc, M ;
Philippon, F ;
Yee, R ;
Lacombe, P ;
Rose, MS ;
Kerr, CD .
CIRCULATION, 1999, 99 (19) :2553-2558
[5]   The atrial pacing peri-ablation for paroxysmal atrial fibrillation (PA3) study -: Rationale and study design [J].
Gillis, AM .
EUROPACE, 1999, 1 (01) :40-42
[6]   EFFECTS OF LEFT-VENTRICULAR DYSFUNCTION ON THE CIRCADIAN VARIATION OF VENTRICULAR PREMATURE COMPLEXES IN HEALED MYOCARDIAL-INFARCTION [J].
GILLIS, AM ;
PETERS, RW ;
MITCHELL, LB ;
DUFF, HJ ;
MCDONALD, M ;
WYSE, DG .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) :1009-1014
[7]   DOUBLE-PEAKING CIRCADIAN VARIATION IN THE OCCURRENCE OF SUSTAINED SUPRAVENTRICULAR TACHYARRHYTHMIAS [J].
KUPARI, M ;
KOSKINEN, P ;
LEINONEN, H .
AMERICAN HEART JOURNAL, 1990, 120 (06) :1364-1369
[8]   CIRCADIAN VARIATION OF SUSTAINED VENTRICULAR-TACHYCARDIA IN PATIENTS WITH CORONARY-ARTERY DISEASE AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
LAMPERT, R ;
ROSENFELD, L ;
BATSFORD, W ;
LEE, F ;
MCPHERSON, C .
CIRCULATION, 1994, 90 (01) :241-247
[9]   PROSPECTIVE EVIDENCE OF A CIRCADIAN-RHYTHM FOR OUT-OF-HOSPITAL CARDIAC ARRESTS [J].
LEVINE, RL ;
PEPE, PE ;
FROMM, RE ;
CURKA, PA ;
CLARK, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (21) :2935-2937
[10]  
MOTULSKY HJ, 1994, GRAPHPAD PRISM VERSI, P267