Patella resurfacing in total knee replacement: functional evaluation and complications

被引:25
作者
Aglietti, P [1 ]
Baldini, A [1 ]
Bussi, R [1 ]
Indelli, PF [1 ]
机构
[1] Univ Florence, Orthoped Clin 1, I-50139 Florence, Italy
关键词
patella reconstruction; yotal knee reconstruction; total knee replacement; patellar resurfacing;
D O I
10.1007/s001670000160
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three different knee replacements, with three trochlear designs, were prospectively evaluated clinically and radiographically for patellar function and presence of patellar complications. They included the Insall-Burstein (IB) I and the IB-II (posterior cruciate ligament substituting) and the Meniscal Bearing Knee (MBK; posterior cruciate ligament recession). The trochlea of the IB-I was short and shallow with an anterior sharp edge of the intercondylar box (later modified to a smoother edge) and the femoral component had a prominent "shoulder." In the IF-II the trochlea was deeper to allow for soft tissue clearance. In the MBK the trochlea was more prolonged, with R and L components and the "shoulder" was less prominent. In all the cases the patella was resurfaced with an all polyethylene dome prosthesis. Knees with tibiofemoral problems were excluded. From the data of the present study the following conclusions can be drawn: (a) The most frequent problem was impingement (clunks) with the early version of the IB-I. Smoothening of the anterior edge significantly reduced the incidence of dunks to 5% in the modified IB I. (b) With the IB-II deepening the trochlea for soft tissue clearance improved the degree, not the incidence of dunks (4.5%), compared to the modified IB I. (c) With the MBK dunks were very rare and patellar function improved. (d) Throughout the three series patellar stress fractures and instability were rare and loosening or wear not evident. (e) Normal function (including stairs ascending and descending) can be expected in over 80% of category A patients. (f) Of the various radiological parameters only patella baja was correlated with symptoms in the IB prostheses. (g) We still prefer the dome design because is more tolerant and with cold flow may better conform to the trochlea increasing contact area.
引用
收藏
页码:S27 / S33
页数:7
相关论文
共 54 条
[1]
AGLIETTI P, 1975, CLIN ORTHOP RELAT R, P175, DOI 10.1097/00003086-197503000-00023
[2]
Aglietti P, 1988, J Arthroplasty, V3, P17, DOI 10.1016/S0883-5403(88)80049-4
[3]
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, V287, P170
[4]
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[5]
BINDELGLASS DF, 1993, CLIN ORTHOP RELAT R, V286, P103
[6]
LONG-TERM COMPLICATIONS AFTER TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT RESURFACING OF THE PATELLA [J].
BOYD, AD ;
EWALD, FC ;
THOMAS, WH ;
POSS, R ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :674-681
[7]
Brick GW, 1988, CLIN ORTHOP RELAT R, V231, P163
[8]
Brumbrach A, 1988, PERFORMANCE MANAGEME, P115
[9]
CLAYTON ML, 1982, CLIN ORTHOP RELAT R, V170, P152
[10]
DEMUTH BC, 1997, 64 ANN M AAOS SAN FR