Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty A randomized RSA and bone mineral densitometry study of 50 hips

被引:68
作者
Baad-Hansen, Thomas [1 ]
Kold, Soren [1 ]
Nielsen, Poul Torben [2 ]
Laursen, Mogens Berg [2 ]
Christensen, Poul Hedevang [2 ]
Soballe, Kjeld [1 ]
机构
[1] Aarhus Univ Hosp, Dept Orthopaed Surg, Aarhus, Denmark
[2] Aalborg Univ Hosp, No Orthopaed Div, Aalborg, Denmark
关键词
ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS; MODEL-BASED RSA; ACETABULAR COMPONENT; COATED CUPS; SCREWS; HYDROXYAPATITE; INTERFACE; MIGRATION; FIXATION; INGROWTH;
D O I
10.3109/17453674.2011.572251
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background Trabecular metal has shown promising results in experimental studies of bone ingrowth. Several clinical studies support these results. However, until now, no randomized clinical radiostereometric analysis (RSA) studies have been published. In this randomized RSA trial, we compared a new acetabular cup with a surface made of tantalum trabecular metal and a cup with a titanium fiber-mesh surface. Patients and methods Between 2004 and 2006, we operated 60 patients with noninflammatory hip arthritis. The patients were randomized to receive either an uncemented cup with a titanium fiber-mesh surface (Trilogy cup) or a cup with a trabecular tantalum surface (Monoblock cup). After 2 years, 50 patients had completed the study. The primary endpoint was cup migration within the first 2 years after surgery; the secondary endpoints were change in bone mineral density and Harris hip score at 3 months. Results Both cup types showed excellent fixation. RSA revealed minimal translation and rotation at 2 years. There was no statistically significant difference between the cup types with regard to translation. However, less rotation along the transverse axis was seen in the trabecular metal cups than in the fiber mesh cups: mean -0.01 degrees (95% CI: -0.11 to 0.12) for trabecular metal cups and -0.60 degrees (-0.72 to -0.48) for fiber-mesh cups (p = 0.04). The degree of periprosthetic bone loss was similar between the cup types in any of the regions of interest at 2 years of follow-up. 3 months postoperatively, we found a similar increase in Harris hip score in both groups: from around 50 to over 90. Interpretation We found promising early results concerning fixation of trabecular metal components to the acetabular host bone. However, we recommend a longer observation period to evaluate the outcome of this new cup design.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 27 条
[1]
High-precision measurements of cementless acetabular components using model-based RSA - An experimental study [J].
Baad-Hansen, Thomas ;
Kold, Soren ;
Kaptein, Bart L. ;
Soballe, Kjeld .
ACTA ORTHOPAEDICA, 2007, 78 (04) :463-469
[2]
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[3]
Tissue response to porous tantalum acetabular cups - A canine model [J].
Bobyn, JD ;
Toh, KK ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :347-354
[4]
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[5]
Cohen Robert, 2002, Am J Orthop (Belle Mead NJ), V31, P216
[6]
Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation [J].
Engh, CA ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :54-60
[7]
GONZALEZ DV, 2004, J ARTHROPLASTY, V19, P972, DOI DOI 10.1016/J.ARTH.2004.06.001
[8]
Radiographic evaluation of a monoblock acetabular component - A multicenter study with 2-to 5-year results [J].
Gruen, TA ;
Poggie, RA ;
Lewallen, DG ;
Hanssen, AD ;
Lewis, RJ ;
O'Keefe, TJ ;
Stulberg, SD ;
Sutherland, CJ .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :369-378
[9]
A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem [J].
Kaptein, BL ;
Valstar, ER ;
Stoel, BC ;
Rozing, PM ;
Reiber, JHC .
JOURNAL OF BIOMECHANICS, 2005, 38 (11) :2330-2334
[10]
Evaluation of three pose estimation algorithms for model-based Roentgen stereophotogrammetric analysis [J].
Kaptein, BL ;
Valstar, ER ;
Stoel, BC ;
Rozing, PM ;
Reiber, JHC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H4) :231-238