Doubled stenting for effective occlusion of a dissecting carotid artery aneurysm

被引:7
作者
Benndorf, G [1 ]
Wellnhofer, E [1 ]
Schneider, GH [1 ]
机构
[1] Humboldt Univ, Dept Radiol, Charite, D-13353 Berlin, Germany
来源
INTERVENTIONAL NEURORADIOLOGY | 2000年 / 6卷 / 04期
关键词
carotid artery; cerebral infarction; dissecting aneurysm; doubled stenting;
D O I
10.1177/159101990000600411
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Endovascular stent placement for of symptomatic pseudoaneurysms in extracranial carotid arteries proved safe and effective. We aimed at increasing the efficacy of stenting for treatment of an internal carotin artery (ICA) dissecting aneurysm by reducing the stent porosity through placement of oversized overlapping stents. A 55-year-old woman presented with right sided hemiplegia and aphasia. CT revealed an infarction in the left hemisphere, and cerebral angiography showed an extracranial dissection of the left ICA with a 1.0 x 2.0 cm pseudoaneurysm at the CI-level, Two oversized self-expandable stents (8/30, 8/40 Wallstent) were placed, bridging the dissected segment and overlapping at the level of the aneurysmal neck. Immediate control angiography showed remark ably reduced filling of the pseudoaneurysm. Intravascular flow assessment depicted a significant reduction of intraaneurysmal flow (31/0 cm/s). Follow-up arteriograms performed after six days and nine months confirmed complete disappearance of the pseudoaneurysm and a patent vessel lumen. Reduced stent porosity causes significant haemodynamic changes inside the aneurysmal sac and accelerates intraaneurysmal thrombosis. Deployment of oversized and overlapping stents may be helpful in achieving rapid complete occlusion and avoiding additional coil packing.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 27 条
[1]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]  
Benndorf G, 1996, AM J NEURORADIOL, V17, P1333
[3]   Treatment of traumatic carotid pseudoaneurysm with endovascular stent placement [J].
Bernstein, SM ;
Coldwell, DM ;
Prall, JA ;
Brega, KE .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (06) :1065-1068
[4]   Treatment of blunt injury to the carotid artery by using endovascular stents: an early experience [J].
Duke, BJ ;
Ryu, RK ;
Coldwell, DM ;
Brega, KE .
JOURNAL OF NEUROSURGERY, 1997, 87 (06) :825-829
[5]   Blunt carotid injury - Importance of early diagnosis and anticoagulant therapy [J].
Fabian, TC ;
Patton, JH ;
Croce, MA ;
Minard, G ;
Kudsk, KA ;
Pritchard, FE .
ANNALS OF SURGERY, 1996, 223 (05) :513-522
[6]   Long-term follow-up of aneurysms developed during extracranial internal carotid artery dissection [J].
Guillon, B ;
Brunereau, L ;
Biousse, V ;
Djouhri, H ;
Lévy, C ;
Bousser, MG .
NEUROLOGY, 1999, 53 (01) :117-122
[7]  
Horowitz MB, 1996, AM J NEURORADIOL, V17, P693
[8]   The use of stents in the management of neurovascular disease: A review of historical and present status [J].
Horowitz, MB ;
Purdy, PD .
NEUROSURGERY, 2000, 46 (06) :1335-1342
[9]   Endovascular stent treatment of cervical internal carotid artery aneurysms with parent vessel preservation [J].
Hurst, RW ;
Haskal, ZJ ;
Zager, E ;
Bagley, LJ ;
Flamm, ES .
SURGICAL NEUROLOGY, 1998, 50 (04) :313-317
[10]  
Klein GE, 1997, AM J NEURORADIOL, V18, P1261