Effectiveness of abdominal compression during helical renal CT

被引:33
作者
Caoili, EM [1 ]
Cohan, RH [1 ]
Korobkin, M [1 ]
Platt, JF [1 ]
Francis, IR [1 ]
Gebremariam, A [1 ]
Ellis, JH [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computed tomography; helical; ureter; CT; urography;
D O I
10.1016/S1076-6332(03)80721-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors performed this study to assess the effect of abdominal compression on opacification and distention of the proximal renal collecting system during helical computed tomography (CT). Materials and Methods. Abdominal compression was applied during helical CT in 31 patients who were scanned 150 and 300 seconds after initiating a dynamic bolus injection of contrast material. Two reviewers assessed renal collecting system opacification and measured the maximal short-axis diameter of the collecting system at three locations: the upper pole, the lower pole, and the proximal ureter. A similar evaluation was performed in a control group of 29 patients who under-went CT without compression at 300 seconds after initiating the injection of contrast material. Results. Both reviewers noted collecting system opacification at all locations in 52 of 56 noncompressed collecting systems scanned at 300 seconds, 57 of 59 compressed collecting systems scanned at 300 seconds, but only 26 of 59 compressed collecting systems scanned at 150 seconds. Measured collecting system distention was statistically significantly greater at 300 seconds in patents who received compression than in patients who did not (P = .0013). For patients who received compression, measured collecting system distention was statistically significantly greater on scans obtained at 300 seconds than on scans obtained at 150 seconds (P = .0001). Conclusion. Abdominal compression during renal helical CT produces a detectable increase in renal collecting system distention. In patients who receive compression, scanning at 300 seconds rather than at 150 seconds results in greater collecting system distention and more consistent opacification.
引用
收藏
页码:1100 / 1106
页数:7
相关论文
共 12 条
[1]   RENAL MASSES - ASSESSMENT OF CORTICOMEDULLARY-PHASE AND NEPHROGRAPHIC-PHASE CT SCANS [J].
COHAN, RH ;
SHERMAN, LS ;
KOROBKIN, M ;
BASS, JC ;
FRANCIS, IR .
RADIOLOGY, 1995, 196 (02) :445-451
[2]   Spiral CT in the evaluation of flank pain: Overall accuracy and feature analysis [J].
Fielding, JR ;
Fox, LA ;
Heller, H ;
Seltzer, SE ;
Tempany, CM ;
Silverman, SG ;
Steele, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :635-638
[3]   Compression CT urography: A comparison with IVU in the opacification of the collecting system and ureters [J].
Heneghan, JP ;
Kim, DH ;
Leder, RA ;
DeLong, D ;
Nelson, RC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (03) :343-347
[4]   Unenhanced helical CT of ureteral stones: Incidence of associated urinary tract findings [J].
Katz, DS ;
Lane, MJ ;
Sommer, FG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1319-1322
[5]   Excretory phase CT urography for opacification of the urinary collecting system [J].
McNicholas, MMJ ;
Raptopoulos, VD ;
Schwartz, RK ;
Sheiman, RG ;
Zormpala, A ;
Prassopoulos, PK ;
Ernst, RD ;
Pearlman, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1261-1267
[6]  
O'Malley ME, 1999, RADIOLOGY, V213P, P474
[7]  
Roy C, 1999, RADIOLOGY, V213P, P475
[8]   ACUTE FLANK PAIN - COMPARISON OF NON-CONTRAST-ENHANCED CT AND INTRAVENOUS UROGRAPHY [J].
SMITH, RC ;
ROSENFIELD, AT ;
CHOE, KA ;
ESSENMACHER, KR ;
VERGA, M ;
GLICKMAN, MG ;
LANGE, RC .
RADIOLOGY, 1995, 194 (03) :789-794
[9]   Radiologic investigation of renal colic: Unenhanced helical CT compared with excretory urography [J].
Sourtzis, S ;
Thibeau, JF ;
Damry, N ;
Raslan, A ;
Vandendris, M ;
Bellemans, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1491-1494
[10]  
SUSSMAN SK, 1993, ABDOM IMAGING, V18, P180