摘要
A spectrophotometric method for the determination of total carbonate in water samples was developed. The method is based on the color change of an acid-base indicator in relation to the concentration of permeable gas substances through a membrane. By using a new portable FIA system equipped with a gas-diffusion unit, a highly sensitive and on-site determination of total carbonate in aqueous solutions was investigated. A new color-change system with 4-(2',4'-dinitrophenylazo)-1-naphthol-5-sulfonic acid (DNN5S) was developed. Absorbance changes of the reagent solution were measured at 450 nm with a light-emitting diode (LED) as a light source. A new type of gas-diffusion unit was used, and was constructed with double tubing: the inner tubing was a micro porous PTFE (polytetrafluoroethylene) tubing (1.0 min inner diameter and 1.8 min outer diameter, pore size 2 mum, porosity 50%); the outer tubing was made of glass with 2.0 min inner diameter. The optimized system conditions were as follows: the sample size was 200 mul, the temperature of the air bath for the gas-diffusion unit was 25 degreesC, and the length of the gas-diffusion unit was 15 cm; each flow rate was 0.3 ml min(-1). For measuring carbonate at low concentrations, a method for preparing water with less carbonate was proposed: the carbonate content of the water was decreased down to 5 x 10(-7) M. The calibration graph was rectilinear from 1 x 10(-6) M to 10(-3) M, and the detection limit (corresponding to a signal-to-noise ratio of 3) was 1 X 10(-6) M of carbonate. The relative standard deviation (RSD) of ten measurements of 2.3 x 10(-5) M Na2CO3 solution was 1.9%. The total carbonate in various kinds of water (such as river, sea, rain, distilled and ultra purified) was determined.
引用
收藏
页码:1285 / 1290
页数:6
相关论文
共 13 条
[1]   CONTINUOUS-FLOW METHOD FOR THE DETERMINATION OF TOTAL INORGANIC CARBONATE IN WATER [J].
AOKI, T ;
FUJIMARU, Y ;
OKA, Y ;
FUJIE, K .
ANALYTICA CHIMICA ACTA, 1993, 284 (01) :167-171
[3]  
Higuchi K, 1999, BUNSEKI KAGAKU, V48, P253
[4]   COMPARISON OF PHOTOMETRY AND CONDUCTOMETRY FOR THE DETERMINATION OF TOTAL CARBONATE BY GAS PERMEATION FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
DASGUPTA, PK .
TALANTA, 1993, 40 (06) :831-840
[5]  
KUWAKI T, 1987, BUNSEKI KAGAKU, V36, pT132
[6]  
KUWAKI T, 1987, BUNSEKI KAGAKU, V36, pT81
[7]   SIMULTANEOUS DETERMINATION OF CARBON-DIOXIDE AND SULFUR-DIOXIDE IN WINE BY GAS-DIFFUSION FLOW-INJECTION ANALYSIS [J].
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :443-448
[8]  
MA L, 2000, J FLOW INJECTION ANA, V17, P188
[9]  
MOTOMIZU S, 1987, ANAL CHEM, V592, P930
[10]  
SANADA M, 1993, BUNSEKI KAGAKU, V42, pT123