Electrospray ionization - Tandem mass spectrometry analysis of peptides derived by enzymatic digestion of oxidized globin subunits: An improved method to determine amino acid substitution in the hemoglobin ''core''

被引:11
作者
Nakanishi, T
Miyazaki, A
Kishikawa, M
Shimizu, A
Yonezawa, T
机构
[1] OSAKA MED COLL,DEPT CLIN PATHOL,TAKATSUKI,OSAKA 569,JAPAN
[2] IKEDA CITY HOSP,IKEDA,OSAKA,JAPAN
关键词
D O I
10.1016/1044-0305(96)00028-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of an amino acid substitution in the ''core'' region of abnormal hemoglobin is technically difficult and is time- and labor-intensive both. by conventional and by mass spectrometry techniques. Underivatized subunits cleaved with trypsin and lysyl endopeptidase were analyzed by high-performance liquid chromatography-electrospray ionization-mass spectrometry. The core peptides showed a series of multiply charged ions of homo- and heterodimers. Abnormal peptides in the core region could be detected in dimeric form. The sequence of core peptides was determined by product ion spectra of the peptides from oxidized globin digested with trypsin and lysyl endopeptidase. Oxidation of cysteine residues to cysteic acids in the core region resulted in the strong promotion of y-series ions by product ion analysis with a tryptic peptide from apoprotein B-100 as previously reported by Burlet, Yang, and Gaskell (J. Am. Sec. Mass Spectrom. 1992, 3, 337-344). These techniques were used to prove that substitution of an unstable hemoglobin, known as Ho Santa Ana (beta 88 leucine --> proline), occurred in a patient with congenital hemolytic anemia. The tandem mass spectrometry analysis with oxidized globin digested with trypsin and lysyl endopeptidase offers a novel method to detect substitutions in the core region of hemoglobin.
引用
收藏
页码:1040 / 1049
页数:10
相关论文
共 28 条
[1]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[2]   TANDEM MASS-SPECTROMETRIC CHARACTERIZATION OF A SPECIFIC CYSTEIC ACID RESIDUE IN OXIDIZED HUMAN APOPROTEIN B-100 [J].
BURLET, O ;
YANG, CY ;
GUYTON, JR ;
GASKELL, SJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (04) :242-247
[3]   INFLUENCE OF CYSTEINE TO CYSTEIC ACID OXIDATION ON THE COLLISION-ACTIVATED DECOMPOSITION OF PROTONATED PEPTIDES - EVIDENCE FOR INTRAIONIC INTERACTIONS [J].
BURLET, O ;
YANG, CY ;
GASKELL, SJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :337-344
[4]  
CASTAGNOLA M, 1986, ANAL LETT, V19, P1793
[5]  
DRABKIN DL, 1946, J BIOL CHEM, V164, P703
[6]  
GREEN BN, 1990, BIOLOGICAL MASS SPECTROMETRY /, P129
[7]  
GUIDOTTI G, 1962, J BIOL CHEM, V237, P2184
[8]   UBER HAMOGLOBINE .9. ISOLIERUNG UND CHARAKTERISIERUNG DER TRYPTISCHEN SPALTPRODUKTE DES NORMALEN ADULTEN HUMANHAMOGLOBINS [J].
HILSE, K ;
BRAUNITZER, G .
HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1962, 329 (3-6) :113-&
[9]  
HIRS CHW, 1956, J BIOL CHEM, V219, P611
[10]   COLLISIONAL FRAGMENTATION OF GLYCOPEPTIDES BY ELECTROSPRAY IONIZATION LC MS AND LC MS MS - METHODS FOR SELECTIVE DETECTION OF GLYCOPEPTIDES IN PROTEIN DIGESTS [J].
HUDDLESTON, MJ ;
BEAN, MF ;
CARR, SA .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :877-884