Peri-procedural myocardial injury during percutaneous coronary intervention: an important target for cardioprotection

被引:161
作者
Babu, Girish Ganesha [1 ]
Walker, J. Malcolm [1 ]
Yellon, Derek M. [1 ]
Hausenloy, Derek J. [1 ]
机构
[1] Univ Coll Med Sch, Hatter Cardiovasc Inst, Div Med, London WC1E 6HX, England
关键词
Percutaneous coronary intervention; Ischaemia; Reperfusion; Myocardial infarction; SIDE BRANCH OCCLUSION; CARDIOVASCULAR MAGNETIC-RESONANCE; PLATELET GLYCOPROTEIN IIB/IIIA; OPTICAL COHERENCE TOMOGRAPHY; RANDOMIZED CONTROLLED-TRIAL; INTRACORONARY BETA-BLOCKER; CARDIAC ENZYME ELEVATION; STABLE ANGINA-PECTORIS; KINASE-MB ELEVATION; C-REACTIVE PROTEIN;
D O I
10.1093/eurheartj/ehq393
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Percutaneous coronary intervention (PCI) has become the predominant procedure for coronary revascularization in patients with both stable and unstable coronary artery disease (CAD). Over the past two decades, technical advances in PCI have resulted in a better and safer therapeutic procedure with minimal procedural complications. However, about 30% of patients undergoing elective PCI sustain myocardial injury arising from the procedure itself, the extent of which is significant enough to carry prognostic importance. The peri-procedural injury which accompanies PCI might therefore reduce some of the beneficial effects of coronary revascularization. The availability of more sensitive serum biomarkers of myocardial injury such as creatine phosphokinase MB isoenzyme (CK-MB), Troponin T, and Troponin I has enabled the quantification of previously undetectable myocardial injury. Peri-procedural myocardial injury (PMI) can also be visualized by cardiac magnetic resonance imaging, a technique which allows the detection and quantification of myocardial necrosis following PCI. The identification of CAD patients at greatest risk of sustaining PMI during PCI would allow targeted treatment with novel therapies capable of limiting the extent of PMI or reducing the number of patients experiencing PMI.
引用
收藏
页码:23 / +
页数:12
相关论文
共 134 条
[1]
DIAGNOSIS OF PERIOPERATIVE MYOCARDIAL-INFARCTION WITH MEASUREMENT OF CARDIAC TROPONIN-I [J].
ADAMS, JE ;
SICARD, GA ;
ALLEN, BT ;
BRIDWELL, KH ;
LENKE, LG ;
DAVILAROMAN, VG ;
BODOR, GS ;
LADENSON, JH ;
JAFFE, AS .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 330 (10) :670-674
[2]
Mechanism of lumen enlargement during intracoronary stent implantation - An intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Weissman, NJ ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM .
CIRCULATION, 2000, 102 (01) :7-10
[3]
Minor myocardial damage and prognosis - Are spontaneous and percutaneous coronary intervention-related events different? [J].
Akkerhuis, KM ;
Alexander, JH ;
Tardiff, BE ;
Boersma, E ;
Harrington, RA ;
Lincoff, AM ;
Simoons, ML .
CIRCULATION, 2002, 105 (05) :554-556
[4]
Remote ischemic preconditioning reduces myocardial and renal injury after elective abdominal aortic aneurysm repair - A randomized controlled trial [J].
Ali, Ziad A. ;
Callaghan, Chris J. ;
Lim, Eric ;
Ali, Ayyaz A. ;
Nouraei, S. A. Reza ;
Akthar, Asim M. ;
Boyle, Jonathan R. ;
Varty, Kevin ;
Kharbanda, Rajesh K. ;
Dutka, David P. ;
Gaunt, Michael E. .
CIRCULATION, 2007, 116 (11) :I98-I105
[5]
Incidence and angiographic predictors of side branch occlusion following high-pressure intracoronary stenting [J].
Aliabadi, D ;
Tilli, FV ;
Bowers, TR ;
Benzuly, KH ;
Safian, RD ;
Goldstein, JA ;
Grines, CL ;
ONeill, WW .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08) :994-997
[6]
Distal protection with a filter device during coronary stenting in patients with stable and unstable angina [J].
Angelini, A ;
Rubartelli, P ;
Mistrorigo, F ;
Della Barbera, M ;
Abbadessa, F ;
Vischi, M ;
Thiene, G ;
Chierchia, S .
CIRCULATION, 2004, 110 (05) :515-521
[7]
[Anonymous], HEART DIS STROK STAT
[8]
SIDE BRANCH OCCLUSION DURING CORONARY ANGIOPLASTY - INCIDENCE, ANGIOGRAPHIC CHARACTERISTICS, AND OUTCOME [J].
ARORA, RR ;
RAYMOND, RE ;
DIMAS, AP ;
BHADWAR, K ;
SIMPFENDORFER, C .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 18 (04) :210-212
[9]
Baim DS, 1998, CIRCULATION, V97, P322
[10]
Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290