One-year results of a prospective, randomised clinical trial comparing four meshes in laparoscopic inguinal hernia repair (TAPP)

被引:32
作者
Bittner, R. [1 ,4 ]
Leibl, B. J. [2 ]
Kraft, B. [3 ,4 ]
Schwarz, J. [1 ,4 ]
机构
[1] EuromedClin Furth, Hernia Ctr, Dept Gen & Visceral Surg, D-90763 Furth, Germany
[2] Klinikum Coburg, Dept Gen & Visceral Surg, D-96450 Coburg, Germany
[3] Bethesda Krankenhaus Stuttgart, Ctr Minimal Invas Surg, D-70184 Stuttgart, Germany
[4] Marienhosp Stuttgart, Dept Gen & Visceral Surg, D-70199 Stuttgart, Germany
关键词
Inguinal hernia; Laparoscopic hernia repair; TAPP; Lightweight mesh; Fibrin glue fixation; STANDARD POLYPROPYLENE MESH; CHRONIC PAIN; GROIN HERNIA; HEAVYWEIGHT MESH; LIGHTWEIGHT MESH; FIBRIN SEALANT; COMPOSITE MESH; FOLLOW-UP; FIXATION; HERNIOPLASTY;
D O I
10.1007/s10029-011-0810-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background A low rate of chronic pain and maximum postoperative comfort are the main goals today in inguinal hernia repair. This four-arm randomised trial compares these parameters after laparoscopic hernia repair (TAPP) with a standard heavyweight mesh (HW), a pure middleweight polypropylene mesh (MW), a lightweight composite polypropylene mesh (LW), or a titanised lightweight mesh (TLW). The primary endpoint of the study was the incidence of chronic pain of any severity at the site of hernia repair at 1 year. Methods A total of 600 patients with a laparoscopic inguinal hernia repair and a defect diameter of 3-5 cm were included in the trial. In all patients, a non-invasive mesh fixation technique was performed using fibrin glue. Patients were assessed for pain, foreign body sensation, and physical activities preoperatively, early postoperatively, at 4 weeks, at 6 months, and at 1 year by questionnaire, and were examined clinically. Postoperatively, seroma formation was measured by ultrasound. Results At 1 year after TAPP, frequency of pain did not differ statistically between the four groups (depending on type of activity: between 6-8% with HW mesh, 2-4% with middleweight mesh, and 2-4.7% with both lightweight meshes); average intensity of pain was very low, at between VAS 0.4 +/- 3.1 and 1.5 +/- 7.8 (MW, LW, TLW) and between 1.9 +/- 8.6 and 2.3 +/- 9.1 (HW) depending on activity (n.s.). Early postoperatively between 31.3% (LW) and 21.3% (TLW) of the patients needed pain medication (n.s.); at 1 year this percentage had dropped to 0.3% (one HW, one MW). Foreign body sensation did not differ but impairment of physical activities (P = 0.0437) was significantly less in the MW, LW, and TLW group (6-12.7%) compared to HW (15.3%) at 4 weeks; at 1 year this percentage was between 0 and 1.3% (n.s.). Conclusion Compared to HW mesh, the use of MW, LW, and TLW meshes for laparoscopic hernia repair did not significantly affect rate of chronic pain, but seemed to improve early postoperative convalescence. No difference was found between middleweight pure polypropylene (MW), composite lightweight (LW), or titanised lightweight polypropylene (TLW) meshes.
引用
收藏
页码:503 / 510
页数:8
相关论文
共 36 条
[1]   Chronic postoperative pain: the case of inguinal herniorrhaphy [J].
Aasvang, E ;
Kehlet, H .
BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (01) :69-76
[2]   Predictive Risk Factors for Persistent Postherniotomy Pain [J].
Aasvang, Eske K. ;
Gmaehle, Eliza ;
Hansen, Jeanette B. ;
Gmaehle, Bjorn ;
Forman, Julie L. ;
Schwarz, Jochen ;
Bittner, Reinhard ;
Kehlet, Henrik .
ANESTHESIOLOGY, 2010, 112 (04) :957-969
[3]   Prospective double-blind randomized controlled study comparing heavy- and lightweight polypropylene mesh in totally extraperitoneal repair of inguinal hernia: early results [J].
Agarwal, Brij B. ;
Agarwal, Krishna Adit ;
Mahajan, Krishan C. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (02) :242-247
[4]   New understanding of the causes and surgical treatment of postherniorrhaphy inguinodynia and orchalgia [J].
Amid, Parviz K. ;
Hiatt, Jonathan R. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2007, 205 (02) :381-385
[5]  
[Anonymous], PAIN
[6]   Chronic pain after open mesh and sutured repair of indirect inguinal hernia in young males [J].
Bay-Nielsen, M ;
Nilsson, E ;
Nordin, P ;
Kehlet, H .
BRITISH JOURNAL OF SURGERY, 2004, 91 (10) :1372-1376
[7]   Laparoscopic transperitoneal procedure for routine repair of groin hernia [J].
Bittner, R ;
Schmedt, CG ;
Schwarz, J ;
Kraft, K ;
Leibl, BJ .
BRITISH JOURNAL OF SURGERY, 2002, 89 (08) :1062-1066
[8]  
Bittner R, 2003, LAPAROSCOPIC HERNIA, P53
[9]  
Bittner R, 2006, CHIRURG LEISTENHERNI, P115
[10]   Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia [J].
Bringman, S. ;
Wollert, S. ;
Osterberg, J. ;
Smedberg, S. ;
Granlund, H. ;
Heikkinen, T. -J. .
BRITISH JOURNAL OF SURGERY, 2006, 93 (09) :1056-1059