Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: Assessment of target coverage and noninvolved tissue sparing

被引:153
作者
Eisbruch, A [1 ]
Marsh, LH
Martel, MK
Ship, JA
Ten Haken, R
Pu, AT
Fraass, BA
Lichter, AS
机构
[1] Univ Michigan, Ctr Med, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ctr Med, Dept Hosp Dent, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 41卷 / 03期
关键词
head and neck cancer; intensity modulation; conformal; irradiation; salivary glands; parotid gland;
D O I
10.1016/S0360-3016(98)00082-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Conformal treatment using static multisegmental intensity modulation was developed for patients requiring comprehensive irradiation for head and neck cancer. The major aim is sparing major salivary gland function while adequately treating the targets. To assess the adequacy of the conformal plans regarding target coverage and dose homogeneity, they were compared with standard irradiation plans. Methods and Materials: Fifteen patients with stage III/IV head and neck cancer requiring comprehensive, bilateral neck irradiation participated in this study. CT-based treatment plans included five to six nonopposed fields, each having two to four in-field segments. Fields and segments were devised using beam's eye views of the planning target volumes (PTVs), noninvolved organs, and isodose surfaces, to achieve homogeneous dose distribution that encompassed the targets and spared major salivary gland tissue. For comparison, standard three-held radiation plans were devised retrospectively for each patient, with the same CT-derived targets used for the clinical (conformal) plans. Saliva flow rates from each major salivary gland were measured before and periodically after treatment. Results: On average, the minimal dose to the primary PTVs in the conformal plans [95.2% of the prescribed dose, standard deviation (SD) 4%] was higher than in the standard plans (91%, SD 7%; p = 0.02), and target volumes receiving <95% or <90% of the prescribed dose were smaller in the conformal plans (p = 0.004 and 0.02, respectively). Similar advantages of the conformal plans compared to standard plans were found in ipsilateral jugular nodes PTV coverage. The reason for underdosing in the standard treatment plans was primarily failure of electron beams to fully encompass targets. No significant differences were found in contralateral jugular or posterior neck nodes coverage. The minimal dose to the retropharyngeal nodes was higher in the standard plans. However, all conformal plans achieved the planning goal of delivering 50 Gy to these nodes. In the conformal plans, the magnitude and volumes of high doses in noninvolved tissue were significantly reduced. The main reasons for hot spots in the standard plans (whose dose calculations included missing tissue compensators) were photon/electron match line inhomogeneities, which were avoided in the conformal plans. The mean doses to all the major salivary glands, notably the contralateral parotid (receiving on average 32% of the prescribed dose, SD 7%) were significantly lower in the conformal plans compared with standard radiation plans. The mean dose to the noninvolved oral cavity tended to be lower in the conformal plans (p = 0.07). One to 3 months after radiation, on average 60% (SD 49%) of the preradiation saliva how rate was retained in the contralateral parotid glands and 10% (SD 16%) was retained in the submandibular/sublingual glands. Conclusions: Planning and delivery of comprehensive irradiation for head and neck cancer using static, multisegmental intensity modulation are feasible. Target coverage has not been compromised and dose distributions in noninvolved tissue are favorable compared with standard radiation. Substantial major salivary gland function can be retained. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:559 / 568
页数:10
相关论文
共 33 条
[1]  
Ang KK, 1994, RADIOTHERAPY HEAD NE, P15
[2]   3-DIMENSIONAL PHOTON TREATMENT PLANNING IN CARCINOMA OF THE LARYNX [J].
COIA, L ;
GALVIN, J ;
SONTAG, M ;
BLITZER, P ;
BRENNER, H ;
CHENG, E ;
DOPPKE, K ;
HARMS, W ;
HUNT, M ;
MOHAN, R ;
MUNZENRIDER, J ;
SIMPSON, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :183-192
[3]   LATE EFFECTS OF RADIATION-THERAPY IN THE HEAD AND NECK REGION [J].
COOPER, JS ;
FU, K ;
MARKS, J ;
SILVERMAN, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (05) :1141-1164
[4]   Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator [J].
DeNeve, W ;
DeWagter, C ;
DeJaeger, K ;
Thienpont, M ;
Colle, C ;
Derycke, S ;
Schelfhout, J .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (03) :271-279
[5]   Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results [J].
Eisbruch, A ;
Ship, JA ;
Martel, MK ;
TenHaken, RK ;
Marsh, LH ;
Wolf, GT ;
Esclamado, RM ;
Bradford, CR ;
Terrell, JE ;
Gebarski, SS ;
Lichter, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (02) :469-480
[6]  
Emami B, 1996, Front Radiat Ther Oncol, V29, P207
[7]  
Fraass, 1995, Semin Radiat Oncol, V5, P77, DOI 10.1016/S1053-4296(95)80002-6
[8]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P521
[9]   A computer-controlled conformal radiotherapy system .1. Overview [J].
Fraass, BA ;
McShan, DL ;
Kessler, ML ;
Matrone, GM ;
Lewis, JD ;
Weaver, TA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1139-1157
[10]   A computer-controlled conformal radiotherapy system .4. Electronic chart [J].
Fraass, BA ;
McShan, DL ;
Matrone, GM ;
Weaver, TA ;
Lewis, JD ;
Kessler, ML .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1181-1194